The accuracy of joint surface models constructed from data obtained with an electromagnetic tracking device

被引:12
作者
van Ruijven, LJ [1 ]
Beek, M [1 ]
Donker, E [1 ]
van Eijden, TMGJ [1 ]
机构
[1] Acad Ctr Dent Amsterdam, Dept Funct Anat, NL-1105 AZ Amsterdam, Netherlands
关键词
tracking device; articular surface; model; accuracy;
D O I
10.1016/S0021-9290(99)00227-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electromagnetic tracking devices are widely used in biomechanics. In this article a method is evaluated to construct models of articular surfaces using an electromagnetic tracking device. First, the accuracy of the space tracker was examined and optimised. Then, from several joint surfaces random points were measured and eighth degree polynomials were fitted to these measurements. To check if the fit converged well, plots of cross sections of the model with corresponding data points were examined. The accuracy of the models was determined by comparing them with computed tomography data and by reproducibility tests. All the fits converged well to the data. The root mean square (RMS) error of the models varied from 0.07 to 0.18 mm, and was proportional to the size and complexity of the surface. This was mainly due to systematic errors made by the space tracker, which were also proportional to the size and complexity of the surface. (C) 2000 Published Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1023 / 1028
页数:6
相关论文
共 16 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[3]   A B-SPLINE LEAST-SQUARES SURFACE-FITTING METHOD FOR ARTICULAR SURFACES OF DIARTHROIDAL JOINTS [J].
ATESHIAN, GA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :366-373
[4]   QUANTITATION OF ARTICULAR SURFACE-TOPOGRAPHY AND CARTILAGE THICKNESS IN KNEE JOINTS USING STEREOPHOTOGRAMMETRY [J].
ATESHIAN, GA ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :761-776
[5]   Validation of a three-dimensional model of the knee [J].
Blankevoort, L ;
Huiskes, R .
JOURNAL OF BIOMECHANICS, 1996, 29 (07) :955-961
[6]   Accuracy of an electromagnetic tracking device [J].
Bull, AMJ ;
Amis, AA .
JOURNAL OF BIOMECHANICS, 1997, 30 (08) :857-858
[7]   PHOTOGRAMMETRIC TECHNIQUE APPLIED TO ANTHROPOMETRIC STUDY OF HANDS [J].
GHOSH, SK ;
POIRIER, F .
JOURNAL OF BIOMECHANICS, 1987, 20 (07) :729-732
[8]   A 3-DIMENSIONAL ANATOMICAL MODEL OF THE HUMAN PATELLOFEMORAL JOINT, FOR THE DETERMINATION OF PATELLOFEMORAL MOTIONS AND CONTACT CHARACTERISTICS [J].
HEFZY, MS ;
YANG, H .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (04) :289-302
[9]   3-DIMENSIONAL MATHEMATICAL-MODEL ANALYSIS OF THE PATELLOFEMORAL JOINT [J].
HIROKAWA, S .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :659-671
[10]   ANALYTICAL STEREOPHOTOGRAMMETRIC DETERMINATION OF 3-DIMENSIONAL KNEE-JOINT GEOMETRY [J].
HUISKES, R ;
KREMERS, J ;
DELANGE, A ;
WOLTRING, HJ ;
SELVIK, G ;
VANRENS, TJG .
JOURNAL OF BIOMECHANICS, 1985, 18 (08) :559-570