Gadopentetate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning

被引:15
作者
Gupta, AK [1 ]
Alberico, RA [1 ]
Litwin, A [1 ]
Kanter, P [1 ]
Grossman, ZD [1 ]
机构
[1] Roswell Pk Canc Inst, Dept Radiol, Buffalo, NY 14263 USA
关键词
CTA; computed tomographic angiography; gadopentetate dimeglumine;
D O I
10.1097/00004728-200211000-00001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objective: To demonstrate that gadopentetate dimeglumine is potentially an alternative contrast medium for computed tomographic angiography (CTA). Methods: One 12.2-kg Beagle dog was studied as proof of principle; the cervical vessels of three adult human patients were imaged for presurgical planning of the neck. Gadopentetate ditneglumine, 0.5 mol/l (Berlex Laboratories, Wayne, NJ, U.S.A,), a LightSpeed QX/i CT (General Electric Medical Systems, Milwaukee, WI, U.S.A.), and an Ultra Spare 11 (SUN Microsystems, Santa Clara, CA, U.S.A.) running Advantage Windows 3.1 (General Electric Medical Systems) were used. Results: Sufficient enhancement for CTA of the thoracic aorta, cervical vessels, and abdominal vessels was produced in the experimental dog, and the cervical vessels were clearly defined in all three patients. Conclusion: In that subset of patients with contraindications to iodinated contrast medium and for whom magnetic resonance angiography is inappropriate. gadopentetate dimeglumine may be an alternative contrast medium for CTA.
引用
收藏
页码:869 / 874
页数:6
相关论文
共 25 条
[1]
Alberico RA, 1999, AM J NEURORADIOL, V20, P328
[2]
ALBERICO RA, 1995, AM J NEURORADIOL, V16, P1571
[3]
Popliteal vascular disease: Evaluation with spiral CT angiography [J].
Beregi, JP ;
Djabbari, M ;
Desmoucelle, F ;
Willoteaux, S ;
Wattinne, L ;
Louvegny, S .
RADIOLOGY, 1997, 203 (02) :477-483
[4]
Cerebral CT venography [J].
Casey, SO ;
Alberico, RA ;
Patel, M ;
Jimenez, JM ;
Ozsvath, RR ;
Maguire, WM ;
Taylor, ML .
RADIOLOGY, 1996, 198 (01) :163-170
[5]
Castelijns JA, 1996, EUR RADIOL, V6, P156
[6]
Patterns of framework invasion in patients with laryngeal cancer -: Correlation of in vitro magnetic resonance imaging and pathological findings [J].
Declercq, A ;
Van den Hauwe, L ;
Van Marck, E ;
Van de Heyning, PH ;
Spanoghe, M ;
De Schepper, AM .
ACTA OTO-LARYNGOLOGICA, 1998, 118 (06) :892-895
[7]
Fobbe F, 1996, EUR RADIOL, V6, P224
[8]
Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[9]
Gulbins H, 1998, Heart Surg Forum, V1, P111
[10]
LOWER-EXTREMITY SPIRAL CT ANGIOGRAPHY VERSUS CATHETER ANGIOGRAPHY [J].
LAWRENCE, JA ;
KIM, D ;
KENT, KC ;
STEHLING, MK ;
ROSEN, MP ;
RAPTOPOULOS, V .
RADIOLOGY, 1995, 194 (03) :903-908