Sensitive determination of amino acids in kelp by reversed phase high performance liquid chromatography with precolumn derivatization using phenylisothiocyanate

被引:10
作者
Shang, SF
Wang, H
机构
[1] Department of Chemistry, University of Hebei, Baoding
关键词
column liquid chromatography; kelp; microwave hydrolysis; precolumn derivatization; phenylisothiocyanate;
D O I
10.1007/BF02271001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reversed phase high performance liquid chromatographic (RP-HPLC) method for the analysis of amino acids in kelp, using precolumn derivatization, is described. Phenylisothiocyanate (PITC) was used as the reagent for derivatization. The kelp samples were prepared by microwave hydrolysis in only 5 min; seventeen PTC amino acids were separated after hydrolysis and derivatization within 12 min. The coefficients of variation were > 1.94 and the correlation coefficients for concentration versus response were > 0.999 for all derivatives. The ratio of branched amino acid (BAA) to aromatic amino acid (AAA) was also studied. The method has the advantage of shorter hydrolysis and analysis times with optimum separation. In addition, it gives high repeatability of retention times and peak areas for all the amino acids present.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 10 条
[1]   RAPID ANALYSIS OF AMINO-ACIDS USING PRE-COLUMN DERIVATIZATION [J].
BIDLINGMEYER, BA ;
COHEN, SA ;
TARVIN, TL .
JOURNAL OF CHROMATOGRAPHY, 1984, 336 (01) :93-104
[2]   AMINO-ACID ANALYSES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - AN EVALUATION OF THE USEFULNESS OF PRECOLUMN DNS DERIVATIZATION [J].
DEJONG, C ;
HUGHES, GJ ;
VANWIERINGEN, E ;
WILSON, KJ .
JOURNAL OF CHROMATOGRAPHY, 1982, 241 (02) :345-359
[3]   ENHANCEMENT OF PROTEIN-DETECTION BY MICROWAVE-INDUCED HYDROLYSIS AND OPA DERIVATIZATION [J].
ENGELHARDT, H ;
KRAMER, M ;
WALDHOFF, H .
CHROMATOGRAPHIA, 1990, 30 (9-10) :523-526
[4]  
GU YZ, 1989, YING YANG XUE BAO, V11, P9
[5]  
HEINRIKSON RL, 1984, ANAL BIOCHEM, V136, P65, DOI 10.1016/0003-2697(84)90307-5
[6]   CHEMI-LUMINESCENCE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING N-(4-AMINOBUTYL)-N-ETHYLISOLUMINOL AS A PRECOLUMN LABELING REAGENT [J].
KAWASAKI, T ;
MAEDA, M ;
TSUJI, A .
JOURNAL OF CHROMATOGRAPHY, 1985, 328 (JUN) :121-126
[7]  
KWISHNAMURTI CR, 1984, J CHROMATOGR, V315, P321
[8]   MICROSCALE ISOCRATIC SEPARATION OF PHENYLTHIOHYDANTOIN AMINO-ACID DERIVATIVES [J].
LOTTSPEICH, F .
JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN) :321-327
[9]  
RODNEY WB, 1987, J ASSOC OFF ANA CHEM, V70, P425
[10]  
ZHU TS, 1988, YING YANG XUE BAO, V10, P187