Biological effects in unirradiated human tissue induced by radiation damage up to 1 mm away

被引:235
作者
Belyakov, OV
Mitchell, SA
Parikh, D
Randers-Pehrson, G
Marino, SA
Amundson, SA
Geard, CR
Brenner, DJ
机构
[1] Columbia Univ, Ctr Radiol Res, New York, NY 10032 USA
[2] Res & Environm Surveillance Radiat & Nucl Safety, Radiat Biol Lab, FIN-00881 Helsinki, Finland
[3] Stuyvesant High Sch, New York, NY 10282 USA
关键词
bystander; normal human tissue; radiological risk;
D O I
10.1073/pnas.0505020102
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A central tenet in understanding the biological effects of ionizing radiation has been that the initially affected cells were directly damaged by the radiation. By contrast, evidence has emerged concerning "bystander" responses involving damage to nearby cells that were not themselves directly traversed by the radiation. These long-range effects are of interest both mechanistically and for assessing risks from low-dose exposures, where only a small proportion of cells are directly hit. Bystander effects have been observed largely by using single-cell in vitro systems that do not have realistic multicellular morphology; no studies have as yet been reported in three-dimensional, normal human tissue. Given that the bystander phenomenon must involve cell-to-cell interactions, the relevance of such single-cell in vitro studies is questionable, and thus the significance of bystander responses for human health has remained unclear. Here, we describe bystander responses in a three-dimensional, normal human-tissue system. Endpoints were induction of micronucleated and apoptotic cells. A charged-particle microbeam was used, allowing irradiation of cells in defined locations in the tissue yet guaranteeing that no cells located more than a few micrometers away receive any radiation exposure. Unirradiated cells up to 1 mm distant from irradiated cells showed a significant enhancement in effect over background, with an average increase in effect of 1.7-fold for micronuclei and 2.8-fold for apoptosis. The surprisingly long range of bystander signals in human tissue suggests that bystander responses may be important in extrapolating radiation risk estimates from epidemiologically accessible doses down to very low doses where nonhit bystander cells will predominate.
引用
收藏
页码:14203 / 14208
页数:6
相关论文
共 52 条
[1]  
Agresti A., 1990, Analysis of categorical data
[2]   Morphological and biochemical characterization and analysis of apoptosis [J].
Allen, RT ;
Hunter, WJ ;
Agrawal, DK .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1997, 37 (04) :215-228
[3]   Direct evidence for the participation of gap junction-mediated intercellular communication in the transmission of damage signals from α-particle irradiated to nonirradiated cells [J].
Azzam, EI ;
de Toledo, SM ;
Little, JB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (02) :473-478
[4]  
Barcellos-Hoff MH, 2001, RADIAT RES, V156, P618, DOI 10.1667/0033-7587(2001)156[0618:ESTTMA]2.0.CO
[5]  
2
[6]   Stochastic model of autocrine and paracrine signals in cell culture assays [J].
Batsilas, L ;
Berezhkovskii, AM ;
Shvartsman, SY .
BIOPHYSICAL JOURNAL, 2003, 85 (06) :3659-3665
[7]   A proliferation-dependent bystander effect in primary porcine and human urothelial explants in response to targeted irradiation [J].
Belyakov, OV ;
Folkard, M ;
Mothersill, C ;
Prise, KM ;
Michael, BD .
BRITISH JOURNAL OF CANCER, 2003, 88 (05) :767-774
[8]  
Belyakov OV, 2002, RADIAT PROT DOSIM, V99, P249, DOI 10.1093/oxfordjournals.rpd.a006775
[9]   Direct evidence for a bystander effect of ionizing radiation in primary human fibroblasts [J].
Belyakov, OV ;
Malcolmson, AM ;
Folkard, M ;
Prise, KM ;
Michael, BD .
BRITISH JOURNAL OF CANCER, 2001, 84 (05) :674-679
[10]   CERVICAL TISSUE SHRINKAGE BY FORMALDEHYDE FIXATION, PARAFFIN WAX EMBEDDING, SECTION CUTTING AND MOUNTING [J].
BOONSTRA, H ;
OOSTERHUIS, JW ;
OOSTERHUIS, AM ;
FLEUREN, GJ .
VIRCHOWS ARCHIV A-PATHOLOGICAL ANATOMY AND HISTOPATHOLOGY, 1983, 402 (02) :195-201