Analysis of daylighting benefits for office buildings in Egypt

被引:7
作者
El Mohimen, MA [1 ]
Hanna, G
Krarti, M
机构
[1] Zagazig Univ, Banha Branch, Shoubra Fac Engn, Cairo, Egypt
[2] Housing & Bldg Res Ctr, Cairo, Egypt
[3] Univ Colorado, CEAE Dept, Boulder, CO 80309 USA
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 03期
关键词
D O I
10.1115/1.1877472
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 [动力工程及工程热物理]; 0820 [石油与天然气工程];
摘要
This paper summarizes the results of a simulation analysis to determine the effectiveness of daylighting in reducing electrical energy consumption for office buildings in Egypt. Specifically, the impact on daylighting performance is investigated of window size, building size, daylighting control, and glazing type for three geographical locations in Egypt. It was determined that a window to wall area ratio of 0.20 minimizes the total annual electricity use for office buildings in three Egyptian locations, Cairo, Alexandria, and Aswan. A simplified analysis method is developed based on the analysis results to estimate the annual electrical energy savings attributed to daylighting.
引用
收藏
页码:366 / 370
页数:5
相关论文
共 6 条
[1]
*ASHRAE IESNA, 1999, 9011999 ASHRAEIESNA
[2]
*DOE, 1993, DOE21E
[3]
Erhorn H., 1994, DOCUMENTATION SOFTWA
[4]
*HOUS BUILD RES CT, 2003, EN EFF RES BUILD DRA
[5]
KRARTI M, BUILD ENV, V40, P747
[6]
REA MS, 2000, IESNA LIGHTING HDB R, pCH10