Percutaneous excisional breast biopsy

被引:60
作者
Johnson, AT
Henry-Tillman, RS
Smith, LF
Harshfield, D
Korourian, S
Brown, H
Lane, S
Colvert, M
Klimberg, VS [1 ]
机构
[1] Univ Arkansas Med Sci, Dept Surg, Little Rock, AR 72205 USA
[2] Cent Arkansas Vet Healthcare Syst, Little Rock, AR USA
[3] Univ Arkansas Med Sci, Dept Pathol, Little Rock, AR 72205 USA
[4] Univ Arkansas Med Sci, Dept Radiol, Little Rock, AR 72205 USA
关键词
vacuum-assisted breast biopsy; ultrasonography; outpatient;
D O I
10.1016/S0002-9610(02)01099-1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The utility of the vacuum-assisted breast biopsy device (VABB) under stereotactic guidance is well established. We hypothesized that the complete removal of small benign lesions under ultrasonography guidance in an outpatient setting could be obtained with minimal morbidity with the multidirectional hand held vacuum-assisted biopsy. Methods: Patients enrolled in this study underwent an ultrasound-guided minimally invasive excisional breast biopsy through a 3-mm incision. Removal of the abnormality was accomplished with a handheld 8- or 11-gauge Mammotome. Results: Eighty-one patients had 101 lesions excised. The average (+/- SD) age of the participants was 46.8 +/- 15.4 years. The average size of the lesions was 1.15 +/- 0.43 cm (range 0.5 cm to 2.0 cm). Ninety-four lesions (93%) had benign pathology, five lesions (5%) were malignant, and two (2%) lesions had atypical hyperplasia. Six-month baseline mammogram performed in 71% of patients more than 40 years old documented resolution of percutaneously removed lesions. Conclusions: Vacuum-assisted excisional breast biopsy under ultrasound guidance is an effective technique for the therapeutic management of benign lesions. (C) 2002 Excerpta Medica Inc. All rights reserved.
引用
收藏
页码:550 / 554
页数:5
相关论文
共 16 条
[1]  
Burbank F, 1996, AM SURGEON, V62, P738
[2]   Initial experience with breast biopsy utilizing the advanced breast biopsy instrumentation (ABBI) [J].
Ferzli, GS ;
Hurwitz, JB .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (04) :393-396
[3]   A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system [J].
Fine, RE ;
Israel, PZ ;
Walker, LC ;
Corgan, KR ;
Greenwald, LV ;
Berenson, JE ;
Boyd, BA ;
Oliver, MK ;
McClure, T ;
Elberfeld, J .
AMERICAN JOURNAL OF SURGERY, 2001, 182 (04) :335-340
[4]  
HASSELGREN PO, 1993, SURGERY, V114, P836
[5]  
HOMER MJ, 1992, RADIOL CLIN N AM, V30, P139
[6]   Diagnostic accuracy of vacuum-assisted biopsy device for image-detected breast lesions [J].
Hung, WK ;
Lam, HS ;
Lau, Y ;
Chan, CM ;
Yip, AWC .
ANZ JOURNAL OF SURGERY, 2001, 71 (08) :457-460
[7]   Clip migration in stereotactic biopsy [J].
Kass, R ;
Kumar, G ;
Klimberg, VS ;
Kass, L ;
Henry-Tillman, R ;
Johnson, A ;
Colvert, M ;
Lane, S ;
Harshfield, D ;
Korourian, S ;
Parrish, R ;
Mancino, A .
AMERICAN JOURNAL OF SURGERY, 2002, 184 (04) :325-331
[8]  
Lattanzio V, 2001, TUMORI, V87, pS10
[9]   Ultrasound-guided mammotome vacuum biopsy for the diagnosis of impalpable breast lesions [J].
Meloni, GB ;
Dessole, S ;
Becchere, MP ;
Soro, D ;
Capobianco, G ;
Ambrosini, G ;
Nardelli, GB ;
Canalis, GC .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (05) :520-524
[10]   IMAGE-DIRECTED PERCUTANEOUS BIOPSIES WITH A BIOPSY GUN [J].
PARKER, SH ;
HOPPER, KD ;
YAKES, WF ;
GIBSON, MD ;
OWNBEY, JL ;
CARTER, TE .
RADIOLOGY, 1989, 171 (03) :663-669