摘要
Background and objective: Reliable measurement of diaphragm and peripheral muscle thickness, using diagnostic ultrasound, has only been validated in the erect posture. However, in many clinical populations, including critically ill patients, the erect posture presents logistic difficulties. This study aimed to validate ultrasound measurement of diaphragm and peripheral muscle thickness in the recumbent position. Methods: An observational methodology of repeated but blind ultrasound and anthropometric measurements was applied, to assess inta-rater reliability. Thirteen healthy volunteers (aged 20-73 years) participated. A pneumotachograph was used to target lung volume, as diaphragm thickness was measured from ultrasound at end-expiration, and both 25% and 50% of inspiratory capacity, while semi-recumbent. The thicknesses of the mid-upper arm, mid-forearm and mid-thigh musculature were also measured bilaterally while supine. Results: Diaphragm thickness could be reliably measured at end-expiration (intra-class correlation coefficient (ICC) = 0.990, 95% confidence interval: 0.918-0.998), 25% of inspiratory capacity (ICC = 0.959 (0.870-0.988)) and 50% of inspiratory capacity (ICC = 0.994 (0.980-0.998)). Peripheral muscle thickness measurements were also reliable (ICC = 0.998-1.0). Supine anthropometric measurements of limb segment lengths and girths were highly reproducible. Conclusions: This ultrasound technique has good reliability in recumbent positions, making it useful for application to clinical populations when the erect posture is not practical.
引用
收藏
页码:1136 / 1143
页数:8
相关论文
共 34 条
[1]  
Abu El-Sameed Y, 2006, CHEST, V130, p210S
[2]  
Acute Respiratory Distress Syndrome Network, 2005, PRED BOD WEIGHT CALC
[3]   Intra- and intermuscular variation in human quadriceps femoris architecture assessed in vivo [J].
Blazevich, Anthony J. ;
Gill, Nicholas D. ;
Zhou, Shi .
JOURNAL OF ANATOMY, 2006, 209 (03) :289-310
[4]   Accuracy of weight and height estimation in an intensive care unit: Implications for clinical practice and research [J].
Bloomfield, Roxanna ;
Steel, Elizabeth ;
MacLennan, Graeme ;
Noble, David W. .
CRITICAL CARE MEDICINE, 2006, 34 (08) :2153-2157
[5]   MUSCLE THICKNESS, MEASURED WITH ULTRASOUND, MAY BE AN INDICATOR OF LEAN TISSUE WASTING IN MULTIPLE ORGAN FAILURE IN THE PRESENCE OF EDEMA [J].
CAMPBELL, IT ;
WATT, T ;
WITHERS, D ;
ENGLAND, R ;
SUKUMAR, S ;
KEEGAN, MA ;
FARAGHER, B ;
MARTIN, DF .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (03) :533-539
[6]   Twitch transdiaphragmatic pressure depends critically on thoracoabdominal configuration [J].
Chen, RC ;
Kayser, B ;
Yan, S ;
Macklem, PT .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (01) :54-60
[7]  
Cholette J, 2009, CRIT CARE MED, V37, pA434, DOI 10.1097/CCM.0b013e3181b6e760
[8]   A POWER PRIMER [J].
COHEN, J .
PSYCHOLOGICAL BULLETIN, 1992, 112 (01) :155-159
[9]   Diaphragm thickening during inspiration [J].
Cohn, D ;
Benditt, JO ;
Eveloff, S ;
McCool, FD .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (01) :291-296
[10]   Size and strength of the respiratory and quadriceps muscles in patients with chronic asthma [J].
deBruin, PF ;
Ueki, J ;
Watson, A ;
Pride, NB .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (01) :59-64