Saw cuts in unicompartmental knee arthroplasty: An analysis of sawbone preparations

被引:28
作者
Clarius, Michael [1 ]
Aldinger, Peter R. [1 ]
Bruckner, Thomas [2 ]
Seeger, Joern B. [1 ]
机构
[1] Heidelberg Univ, Dept Orthopaed Surg, D-69118 Heidelberg, Germany
[2] Heidelberg Univ, Inst Med Biometry & Informat, D-69120 Heidelberg, Germany
关键词
Knee arthroplasty; Tibial fracture; Unicompartmental knee; Saw cut; Saw guide; TIBIAL PLATEAU FRACTURE; STRESS-FRACTURE; FAILURE;
D O I
10.1016/j.knee.2008.12.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Unicompartmental knee arthroplasty (UKA) has become a frequently used treatment option for anteromedial osteoarthritis (OA) of the knee due to good clinical and functional results. However, serious complications like tibial plateau fractures have been reported. These can be associated with saw cuts during surgery. The purpose of this study was to analyse saw cuts during Sawbone (R) preparations at instructional unicompartmental knee courses and to identify potential sources of surgical error. One hundred Sawbone (R) preparations were performed by knee surgeons inexperienced with UKA. Sawing errors during preparation were analysed and quantified. Tibial and femoral errors can Occur during preparation. At the proximal tibia three errors can be found: extended vertical cuts (A), extended horizontal cuts (13) and perforation of the posterior cortex. An ascending cut at the posterior femoral condyle (C) is possible during femoral preparation. Errors type A were found at a mean length of 2.4 mm +/- 2.3 mm with a maximum value of 10.1 mm. In 18% errors of more than 4.0 mm were found. Type B errors showed an average value of 2.0 mm +/- +/- 1.7 mm with maximum values of 7.4 mm. Type C errors were found at a mean of 1.3 mm +/- 1.0 mm (maximum value 5.1 mm). Our data showed that in 18% of the cases, vertical cutting errors of more than 4.0 mm occurred in inexperienced surgeons. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:314 / 316
页数:3
相关论文
共 17 条
[1]
*AUSTR ORTH ASS NA, 2006, ANN REP AOA
[2]
Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up [J].
Berger, RA ;
Meneghini, RM ;
Jacobs, JJ ;
Sheinkop, MB ;
Della Valle, CJ ;
Rosenberg, AG ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :999-1006
[3]
Tibial plateau stress fracture - A complication of unicompartmental knee arthroplasty using 4 guide pinholes [J].
Brumby, SA ;
Carrington, R ;
Zayontz, S ;
Reish, T ;
Scott, RD .
JOURNAL OF ARTHROPLASTY, 2003, 18 (06) :809-812
[4]
*CJRR, 2006, 2006 CJRR REP TOT HI
[5]
Registry outcomes of unicompartmental knee arthroplasty revisions [J].
Dudley, Thomas E. ;
Gioe, Terence J. ;
Sinner, Penny ;
Mehle, Susan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (07) :1666-1670
[6]
Felix NA, 1997, CLIN ORTHOP RELAT R, P113
[7]
Goodfellow John, 2002, J Knee Surg, V15, P240
[8]
THE OXFORD KNEE FOR UNICOMPARTMENTAL OSTEO-ARTHRITIS - THE 1ST 103 CASES [J].
GOODFELLOW, JW ;
KERSHAW, CJ ;
BENSON, MKD ;
OCONNOR, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05) :692-701
[9]
Unicompartmental knee arthroplasty for the treatment of unicompartmental osteoarthritis: A systematic study [J].
Griffin, Tabatha ;
Rowden, Neville ;
Morgan, David ;
Atkinson, Robert ;
Woodruff, Peter ;
Maddern, Guy .
ANZ JOURNAL OF SURGERY, 2007, 77 (04) :214-221
[10]
Early failure of unicompartmental knee arthroplasty [J].
Mariani, E. Marc ;
Bourne, Michael H. ;
Jackson, Richard T. ;
Jackson, Scott T. ;
Jones, Portia .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :81-84