Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer

被引:25
作者
Janssen, Jessie C. [1 ]
Le-Ngoc, Lan [1 ]
机构
[1] Ind Res Ltd, Christchurch, New Zealand
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2009年 / 90卷 / 09期
关键词
Muscle strength dynamometer; Rehabilitation; Reliability and validity; AGREEMENT; INSTRUMENT; STRENGTH; BIODEX;
D O I
10.1016/j.apmr.2009.02.021
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
Objective: To assess the reliability of a new hand-held dynamometer (HHD) to perform concentric measurements, and to determine the agreement between the HHD and the criterion standard isokinetic dynamometer. Design: Elbow flexion concentric measurements were performed on a mechanical arm using the HHD and the isokinetic dynamometer. Setting: Engineering laboratory and university strength-testing facility. Participants: Three patient profiles, differing in range of motion (ROM) and strength, were simulated by a mechanical arm. Interventions: Not applicable. Main Outcome Measures: Peak torque and ROM obtained from concentric elbow flexion profiles. Results: Intratester reliabilities, measured with the intraclass correlation coefficient (ICC1,1), of the peak torque and start and end ROM are excellent for both the HHD (.99, .98, and .99, respectively) and the isokinetic dynamometer (.99 for all 3 variables). The angle of peak torque was rated fair to good in intrareliability for both devices, at .64 (HHD) and .69 (isokinetic dynamometer). Validity, measured within the limits of agreement (LOA) between the 2 devices, was clinically acceptable for peak torque and start ROM, although not for end ROM and angle of peak torque. Conclusions: It is possible to use the new HHD to obtain dynamic measurements of joint motion. Intratester reliability of the HHD is excellent and is in clinical acceptable agreement with the isokinetic dynamometer for peak torque and start ROM. End ROM was, however, not in agreement because of a systematic error in the isokinetic dynamometer measurement for I of the 3 tested profiles. Intratester reliabilities of the angle of peak torque were fair to good for both the HHD and isokinetic dynamometer, but the LOA were not clinically acceptable. Stability of the arm and speed of measurement might be confounding factors in this study.
引用
收藏
页码:1541 / 1547
页数:7
相关论文
共 21 条
[1]
Andrews A., 1991, Journal of Human Performance, V1, P35
[2]
ISOKINETIC DYNAMOMETRY - APPLICATIONS AND LIMITATIONS [J].
BALTZOPOULOS, V ;
BRODIE, DA .
SPORTS MEDICINE, 1989, 8 (02) :101-116
[3]
Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[4]
A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) :337-340
[5]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[6]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]
INTERRATER RELIABILITY OF HAND-HELD DYNAMOMETRY [J].
BOHANNON, RW ;
ANDREWS, AW .
PHYSICAL THERAPY, 1987, 67 (06) :931-933
[8]
Dunn J C., 2003, Journal of Geriatric Physical Therapy, V26, P23
[9]
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[10]
A method for comparing manual muscle strength measurements with joint moments during walking [J].
Fosang, Adrienne ;
Baker, Richard .
GAIT & POSTURE, 2006, 24 (04) :406-411