摘要
Background and objective: Liver transplantation is characterized by several changes in intravascular blood volume due to vasodilatation based on neurohumoral mediators, intraoperative bleeding and anaesthesia technique effects. Today, with the transpulmonary indicator dilution technique, cardiac index (CIart) can be evaluated and preload assessed in terms of the intrathoracic blood volume index (ITBVI). The aim was to analyse in patients undergoing liver transplantation two preload variables, pulmonary artery occlusion pressure (PAOP) and ITBVI with respect to cardiac index (CIpa) and stroke volume index (SVIpa), the correlation between ITBVI and PAOP, and secondary the relationship between the changes (Delta) of ITBVI and PAOP and the changes of Clpa and SVIpa, and the relationships between DeltaITBVI and DeltaPAOP. The reproducibility and precision of all CIart and CIpa measurements were also evaluated. Methods: A prospective study was performed in 60 patients monitored with a pulmonary artery catheter and with the PiCCO(R) system. The variables were evaluated with a linear regression model. Results: Linear regression analysis between ITBVI-CIpa and ITBVI-SVIpa were r(2) = 0.47 (P < 0.0001) and r(2) = 0.55 (P < 0.0001) respectively, while PAOP poorly correlated to Clpa (r(2) = 0.02), SVIpa (r(2) = 0.015) and ITBVI (r(2) = 0.002). Only changes in ITBVI were correlated with changes in CIpa (Delta(1), r(2) = 0.37; Delta(2), r(2) = 0.32), and SVIpa (Delta(1), r(2) = 0.60; Delta(2), r(2) = 0.47). The mean bias between CIart and CIpa was 0.13 L min(-1) m(-2) (2 SD = 1.04 L min(-1) m(-2)) (r(2) = 0.86, P < 0.0001). Conclusions: In comparison with PAOP, ITBVI seems a more reliable indicator of cardiac preload in patients undergoing liver transplantation.
引用
收藏
页码:868 / 875
页数:8
相关论文
共 31 条
[1]  
AGGARWAL S, 1987, TRANSPLANT P, V19, P54
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Buhre G, 1999, J CARDIOTHOR VASC AN, V13, P437
[4]  
Buhre W, 2001, EUR J ANAESTH, V18, P662
[5]   Assessment of intrathoracic blood volume. Thermo-dye dilution technique vs single-thermodilution technique [J].
Buhre, W ;
Bendyk, K ;
Weyland, A ;
Kazmaier, S ;
Schmidt, M ;
Mursch, K ;
Sonntag, H .
ANAESTHESIST, 1998, 47 (01) :51-53
[6]  
CARMICHAEL FJ, 1985, ANESTH ANALG, V64, P108
[7]  
CUSACK RJ, 2000, CLIN INTENSIVE CARE, V11, P117
[8]   The pulmonary artery catheter - Friend. foe, or accomplice? [J].
Dalen, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 286 (03) :348-350
[9]   Transesophageal echocardiography and orthotopic liver transplantation: General concepts [J].
De Wolfe, A .
LIVER TRANSPLANTATION AND SURGERY, 1999, 5 (04) :339-340
[10]   Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function [J].
Godje, O ;
Peyerl, M ;
Seebauer, T ;
Dewald, O ;
Reichart, B .
CHEST, 1998, 113 (04) :1070-1077