Noninvasive acoustic cell trapping in a microfluidic perfusion system for online bioassays

被引:218
作者
Evander, Mikael [1 ]
Johansson, Linda
Lilliehorn, Tobias
Piskur, Jure
Lindvall, Magnus
Johansson, Stefan
Almqvist, Monica
Laurell, Thomas
Nilsson, Johan
机构
[1] Lund Univ, Dept Elect Measurements, Lund, Sweden
[2] Lund Univ, Dept Cell & Organism Biol, Lund, Sweden
[3] Lund Univ, Dept Child & Adolescent Psychiat, Lund, Sweden
[4] Uppsala Univ, Dept Engn Sci, Uppsala, Sweden
关键词
D O I
10.1021/ac061576v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Techniques for manipulating, separating, and trapping particles and cells are highly desired in today's bioanalytical and biomedical field. The microfluidic chip-based acoustic noncontact trapping method earlier developed within the group now provides a flexible platform for performing cell- and particle-based assays in continuous flow microsystems. An acoustic standing wave is generated in etched glass channels (600 x 61 mu m(2)) by miniature ultrasonic transducers (550 x 550 x 200 mu m(3)). Particles or cells passing the transducer will be retained and levitated in the center of the channel without any contact with the channel walls. The maximum trapping force was calculated to be 430 +/- 135 pN by measuring the drag force exerted on a single particle levitated in the standing wave. The temperature increase in the channel was characterized by fluorescence measurements using rhodamine B, and levels of moderate temperature increase were noted. Neural stem cells were acoustically trapped and shown to be viable after 15 min. Further evidence of the mild cell handling conditions was demonstrated as yeast cells were successfully cultured for 6 h in the acoustic trap while being perfused by the cell medium at a flowrate of 1 mu L/min. The acoustic microchip method facilitates trapping of single cells as well as larger cell clusters. The noncontact mode of cell handling is especially important when studies on nonadherent cells are performed, e.g., stem cells, yeast cells, or blood cells, as mechanical stress and surface interaction are minimized. The demonstrated acoustic trapping of cells and particles enables cell- or particle-based bioassays to be performed in a continuous flow format.
引用
收藏
页码:2984 / 2991
页数:8
相关论文
共 50 条
[1]  
Andersson H., 2004, Lab-on-Chips for Cellomics, P1, DOI [10.1007/978-1-4020-2975-2_1, DOI 10.1007/978-1-4020-2975-2_1]
[2]   History of optical trapping and manipulation of small-neutral particle, atoms, and molecules [J].
Ashkin, A .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2000, 6 (06) :841-856
[3]   Physical enviroment of 2-D animal cell aggregates formed in a short pathlength ultrasound standing wave trap [J].
Bazou, D ;
Kuznetsova, LA ;
Coakley, WT .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (03) :423-430
[4]  
BERLINGCOURT DA, 2006, BEHAV PIEZOELECTRIC
[5]  
Coakley WT, 1997, TRENDS BIOTECHNOL, V15, P506, DOI 10.1016/S0167-7799(97)01122-0
[6]  
COULSON JM, 1991, PARTICLE TECHNOLOGY, V2, P98
[7]  
DUSCHL C, 2004, LAB ON CHIPS CELLOMI, P83
[8]   Miniaturized solid-phase extraction and sample preparation for MALDI MS using a microfabricated integrated selective enrichment target [J].
Ekström, S ;
Wallman, L ;
Hök, D ;
Marko-Varga, G ;
Laurell, T .
JOURNAL OF PROTEOME RESEARCH, 2006, 5 (05) :1071-1081
[9]   Harnessing dielectric forces for separations of cells, fine particles and macromolecules [J].
Gonzalez, CF ;
Remcho, VT .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :59-68
[10]  
Gor'kov L. P., 1962, SOV PHYS DOKL, V6, P773, DOI DOI 10.1039/C004504G