Neutron activation of chemical reagents exposed to the neutrons released by the JCO criticality accident

被引:5
作者
Muroyama, T [1 ]
Murata, Y [1 ]
Kofuji, H [1 ]
Yamamoto, M [1 ]
Komura, K [1 ]
机构
[1] Kanazawa Univ, Low Level Radioact Lab, Wake, Ishikawa 9231224, Japan
关键词
JCO criticality accident; Tokai-mura; neutron activation; neutron fluence;
D O I
10.1016/S0265-931X(00)00061-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Induced radionuclides in the chemical reagents collected in the JCO's Wet Chemistry Testing Laboratory were measured using HPGe detectors in the Low Level Radioactivity Laboratory (LLRL) and in Ogoya underground laboratory. Radioactive nuclei produced by neutron capture reactions were detected in most of the reagents. Products of the (n, p) reaction were detected only in Raney-Nickel and metallic powder of stainless steel. Preliminary estimation of the neutron fluence was made on the basis of determinations of radionuclide concentrations. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:55 / 59
页数:5
相关论文
共 2 条
[1]  
Erdtmann G., 1976, Neutron Activation Tables
[2]  
KOMURA K, 1997, P 1997 INT S ENV RAD, P56