Biaxial long-stemmed multipronged distal components for revision bone deficit total-wrist arthroplasty

被引:30
作者
Cobb, TK [1 ]
Beckenbaugh, RD [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT ORTHOPED,ROCHESTER,MN 55905
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1996年 / 21A卷 / 05期
关键词
D O I
10.1016/S0363-5023(96)80189-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision total-wrist arthroplasty has a high incidence of complications. Loosening is a signifi cant problem for the distal implant. Because of the high failure rate of single-pronged distal implants after revision total-wrist arthroplasty, a custom multipronged distal component (biaxial total-wrist implant) was designed for use in patients with deficient bone stock who undergo revision operation. Ten cases of total-wrist arthroplasty with a custom long-stemmed multipronged distal component are presented. The preoperative diagnosis was failed total-wrist arthroplasty in 9 cases. Mean time from previous total-wrist arthroplasty to revision procedure was 5.6 years. At fellow-up evaluation (mean, 3.8 years; range, 3.0-4.8 years), 2 patients had undergone arthrodesis: 1 patient at an outside institution 1 year after surgery for periprosthetic fracture of the radius, and 1 patient at our institution for distal implant loosening. The 8 other patients had functional total-wrist arthroplasties. At follow-up evaluation, all patients reported they were satisfied. Six patients reported no pain and 2 reported mild pain. Mean range of motion at follow-up evaluation was within the previously defined limits that allow patients to function in activities of daily living: 78 degrees for supination, 77 degrees for pronation, 39 degrees for extension, 17 degrees for flexion, 12 degrees for radial deviation, and 18 degrees for ulnar deviation. Revision total-wrist arthroplasty with custom long-stemmed, multipronged distal components offers an alternative to those patients with deficient bone stock who refuse arthrodesis. Early results demonstrate greater longevity compared with single-pronged components for revision total-wrist arthroplasty.
引用
收藏
页码:764 / 770
页数:7
相关论文
共 6 条
[1]
BECKENBAUGH RD, 1994, WRIST, P253
[2]
BECKENBAUGH RD, 1993, OPERATIVE HAND SURG, V1, P143
[3]
BECKENBAUGH RD, 1991, JOINT REPLACEMENT AR, P195
[4]
COONEY WP, 1984, CLIN ORTHOP RELAT R, V187, P121
[5]
FUNCTIONAL WRIST MOTION - A BIOMECHANICAL STUDY [J].
PALMER, AK ;
WERNER, FW ;
MURPHY, D ;
GLISSON, R .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1985, 10A (01) :39-46
[6]
REVISION TOTAL WRIST ARTHROPLASTY [J].
RETTIG, ME ;
BECKENBAUGH, RD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (05) :798-804