Intraprocedural and Long-Term Incomplete Occlusion of the Left Atrial Appendage Following Placement of the WATCHMAN Device: A Single Center Experience

被引:81
作者
Bai, Rong [1 ,2 ]
Horton, Rodney P. [1 ,3 ]
Di Biase, Luigi [1 ,3 ,4 ]
Mohanty, Prasant [1 ]
Pump, Agnes [1 ]
Cardinal, Deb [1 ]
Scallon, Chantel [1 ]
Mohanty, Sanghamitra [1 ]
Santangeli, Pasquale [1 ]
Brantes, Mauricio C. [1 ,5 ]
Sanchez, Javier [1 ]
Burkhardt, J. David [1 ]
Zagrodzky, Jason D. [1 ]
Gallinghouse, G. Joseph [1 ]
Natale, Andrea [1 ,3 ,6 ,7 ,8 ]
机构
[1] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX 78705 USA
[2] Huazhong Univ Sci & Technol, Tong Ji Hosp, Dept Internal Med, Tong Ji Med Coll, Wuhan 430074, Hubei, Peoples R China
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Univ Foggia, Dept Cardiol, Foggia, Italy
[5] Univ Chile, Hosp Clin, Santiago, Chile
[6] Stanford Univ, Div Cardiol, Palo Alto, CA 94304 USA
[7] Scripps Clin, San Diego, CA USA
[8] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
关键词
atrial fibrillation; closure; left atrial appendage; stroke; thrombus; WATCHMAN device; FIBRILLATION; WARFARIN; CLOSURE; STROKE; PREVENTION; NEED;
D O I
10.1111/j.1540-8167.2011.02216.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Incomplete LAA Occlusion by WATCHMAN Device. Introduction: Transcatheter left atrial appendage (LAA) closure with the WATCHMAN device has become one of the therapeutic options in atrial fibrillation (AF) patients who are at high risk for ischemic stroke. However, the incidence and evolution of incomplete occlusion of the LAA during and after placement of the WATCHMAN device has not been reported. Methods and Results: Fifty-eight consecutive patients who had undergone WATCHMAN device implant were included in the study. Intraprocedural, 45-day and 12-month transesophageal echocardiogram images were reviewed and analyzed. Peridevice gap was noted in 16 (27.6%), 17 (29.3%), and 20 (34.5%) patients across the 3 time points. Intraprocedural gaps are more likely to be persistent until 12 months and become larger in size over time. New gap also occurs during follow-up even if the LAA was completely sealed at implantation. One patient had an ischemic stroke 4.7 months after implant; another patient developed a left atrial thrombus over the device 21.6 months after implant. Both patients had intraprocedural gap and discontinued warfarin therapy after the 45-day evaluation. Conclusion: Incomplete LAA occlusion with a gap between the WATCHMAN device surface and the LAA wall is relatively common. Intraprocedural gaps are more likely to become bigger over time and persist, while new gaps also occur during follow-up. Further studies are warranted to verify whether the presence and persistence of a peridevice gap is associated with increased risk of thromboembolic event in AF patients implanted with a WATCHMAN device. (J Cardiovasc Electrophysiol, Vol. 23, pp. 455-461, May 2012)
引用
收藏
页码:455 / 461
页数:7
相关论文
共 16 条
[1]   Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation [J].
Blackshear, JL ;
Odell, JA .
ANNALS OF THORACIC SURGERY, 1996, 61 (02) :755-759
[2]   Analysis of the left atrial appendage morphology by intracardiac echocardiography in patients with atrial fibrillation [J].
Blendea, Dan ;
Heist, E. Kevin ;
Danik, Stephan B. ;
Barrett, Conor ;
Ruskin, Jeremy N. ;
Mansour, Moussa .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 31 (03) :191-196
[3]  
Contractor T, 2011, CARDIOL RES PRACT, DOI [10.4061/2001/752808, DOI 10.4061/2001/752808]
[4]   Thrombus formation after left atrial appendage exclusion using an amplatzer cardiac plug device [J].
Cruz-Gonzalez, Ignacio ;
Martin Moreiras, Javier ;
Garcia, Eulogio .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (06) :970-973
[5]   Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial [J].
Holmes, David R. ;
Reddy, Vivek Y. ;
Turi, Zoltan G. ;
Doshi, Shephal K. ;
Sievert, Horst ;
Buchbinder, Maurice ;
Mullin, Christopher M. ;
Sick, Peter .
LANCET, 2009, 374 (9689) :534-542
[6]   Left Atrial Appendage Occlusion Eliminates the Need for Warfarin [J].
Holmes, David R., Jr. ;
Schwartz, Robert S. .
CIRCULATION, 2009, 120 (19) :1919-1926
[7]   Surgical left atrial appendage ligation is frequently incomplete: a transesophageal echocardiographic study [J].
Katz, ES ;
Tsiamtsiouris, T ;
Applebaum, RM ;
Schwartzbard, A ;
Tunick, PA ;
Kronzon, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (02) :468-471
[8]   Left atrial appendage closure with Amplatzer cardiac plug for stroke prevention in atrial fibrillation: Initial Asia-Pacific experience [J].
Lam, Yat-Yin ;
Yip, Gabriel W. K. ;
Yu, Cheuk-Man ;
Chan, Wilson W. M. ;
Cheng, Boron C. W. ;
Yan, Bryan P. ;
Clugston, Richard ;
Yong, Gerald ;
Gattorna, Tim ;
Paul, Vincent .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (05) :794-800
[9]   Left Atrial Appendage Occlusion - Closure or Just the Beginning? [J].
Maisel, William H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (25) :2601-2603
[10]  
Onalan Orhan, 2005, Expert Rev Cardiovasc Ther, V3, P619, DOI 10.1586/14779072.3.4.619