A comparison of quantitative EEG features for neonatal seizure detection

被引:163
作者
Greene, B. R. [1 ]
Faul, S. [1 ]
Marnane, W. P. [1 ]
Lightbody, G. [1 ]
Korotchikova, I. [2 ]
Boylan, G. B. [2 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Elect & Elect Engn, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Dept Paediat & Child Hlth, Cork, Ireland
基金
爱尔兰科学基金会;
关键词
EEG; neonatal seizure; quantitative EEG; feature extraction;
D O I
10.1016/j.clinph.2008.02.001
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: This study was undertaken to identify the best performing quantitative EEG features for neonatal seizures detection from a test set of 21. Methods: Each feature was evaluated on 1-min, artefact-free segments of seizure and non-seizure neonatal EEG recordings. The potential utility of each feature for neonatal seizure detection was determined using receiver operating characteristic analysis and repeated measures t-tests. A performance estimate of the feature set was obtained using a cross-fold validation and combining all features together into a linear discriminant classifier model. Results: Significant differences between seizure and non-seizure segments were found in 19 features for 17 patients. The best performing features for this application were the RMS amplitude, the line length and the number of local maxima and minima. An estimate of the patient independent classifier performance yielded a sensitivity of 81.08% and specificity of 82.23%. Conclusions: The individual performances of 21 quantitative EEG features in detecting electrographic seizure in the neonate were compared and numerically quantified. Combining all features together into a classifier model led to superior performance than that provided by any individual feature taken alone. Significance: The results documented in this study may provide a reference for the optimum quantitative EEG features to use in developing and enhancing neonatal seizure detection algorithms. (c) 2008 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1248 / 1261
页数:14
相关论文
共 55 条
[1]   Automated neonatal seizure detection: A multistage classification system through feature selection basedon relevance and redundancy analysis [J].
Aarabi, A ;
Wallois, F ;
Grebe, R .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (02) :328-340
[2]  
[Anonymous], 1993, Ten Lectures of Wavelets
[3]   A parametric feature extraction and classification strategy for brain-computer interfacing [J].
Burke, DR ;
Kelly, SR ;
de Chazal, P ;
Reilly, RB ;
Finucane, C .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (01) :12-17
[4]   SPATIAL AND TEMPORAL CHARACTERISTICS OF NEONATAL SEIZURES [J].
BYE, AME ;
FLANAGAN, D .
EPILEPSIA, 1995, 36 (10) :1009-1016
[5]   A computer-aided detection of EEG seizures in infants: A singular-spectrum approach and performance comparison [J].
Celka, P ;
Colditz, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (05) :455-462
[6]   Epileptic seizure prediction using hybrid feature selection over multiple intracranial EEG electrode contacts: A report of four patients [J].
D'Alessandro, M ;
Esteller, R ;
Vachtsevanos, G ;
Hinson, A ;
Echauz, J ;
Litt, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (05) :603-615
[7]   Role of cerebral function monitoring in the newborn [J].
de Vries, LS ;
Hellström-Westas, L .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (03) :201-207
[8]   The effect of frequency band on quantitative EEG measures in neonates with Hypoxic-ischaemic encephalopathy [J].
Doyle, O. M. ;
Greene, B. R. ;
Murray, D. M. ;
Marnane, L. ;
Lightbody, G. ;
Boylan, G. B. .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :717-+
[9]   A simple system for detection of EEG artifacts in polysomnographic recordings [J].
Durka, PJ ;
Klekowicz, H ;
Blinowska, KJ ;
Szelenberger, W ;
Niemcewicz, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :526-528
[10]   Line length: An efficient feature for seizure onset detection [J].
Esteller, R ;
Echauz, J ;
Tcheng, T ;
Litt, B ;
Pless, B .
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 :1707-1710