Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: Development and initial evaluation

被引:212
作者
Kim, D
Gilson, WD
Kramer, CM
Epstein, FH
机构
[1] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia Hlth Syst, Dept Biomed Engn, Charlottesville, VA 22908 USA
[3] Univ Virginia Hlth Syst, Dept Internal Med, Charlottesville, VA 22908 USA
[4] Univ Virginia Hlth Syst, Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
关键词
heart; function; MR; myocardium;
D O I
10.1148/radiol.2303021213
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A breath-hold two-dimensional cine magnetic resonance (MR) pulse sequence based on displacement encoding with stimulated echoes (DENSE) for quantitative myocardial motion tracking was developed and evaluated. In the sequence, complementary spatial modulation of magnetization was used for time-independent artifact suppression, and echo-planar imaging was used for rapid data sampling. Twelve healthy volunteers underwent cine DENSE. MR imaging, and six of them also underwent conventional MR imaging myocardial tagging. The circumferential shortening component of strain (E-cc) was measured on cine DENSE MR images and conventional tagged MR images. With complementary spatial modulation of magnetization, 10% or less of the total cine DENSE MR image energy was attributed to an artifact-generating echo during systolic imaging. Two-dimensional intramyocardial displacement and strain were measured at cine DENSE MR imaging with spatial resolution and temporal resolution of 2.7 X 2.7 mm and 60 msec, respectively. E-cc measured at cine DENSE MR imaging correlated well with that measured at conventional MR imaging tagging (slope = 0.88, intercept 0.00, R = 0.87). (C) RSNA, 2004.
引用
收藏
页码:862 / 871
页数:10
相关论文
共 39 条
[1]
Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart [J].
Aletras, AH ;
Wen, H .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :523-534
[2]
Aletras AH, 1999, J MAGN RESON, V140, P41, DOI 10.1006/jmre/1999.1821
[3]
DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI [J].
Aletras, AH ;
Ding, SJ ;
Balaban, RS ;
Wen, H .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :247-252
[4]
MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION [J].
AXEL, L ;
DOUGHERTY, L .
RADIOLOGY, 1989, 171 (03) :841-845
[5]
Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[6]
DEVELOPMENT AND EVALUATION OF TRACKING ALGORITHMS FOR CARDIAC WALL-MOTION ANALYSIS USING PHASE-VELOCITY MR-IMAGING [J].
CONSTABLE, RT ;
RATH, KM ;
SINUSAS, AJ ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :33-42
[7]
Left ventricular motion reconstruction from planar tagged MR images:: a comparison [J].
Declerck, J ;
Denney, TS ;
Öztürk, C ;
O'Dell, W ;
McVeigh, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) :1611-1632
[8]
Epstein FH, 1999, MAGNET RESON MED, V41, P609, DOI 10.1002/(SICI)1522-2594(199903)41:3<609::AID-MRM25>3.0.CO
[9]
2-2
[10]
IMPROVED MYOCARDIAL TAGGING CONTRAST [J].
FISCHER, SE ;
MCKINNON, GC ;
MAIER, SE ;
BOESIGER, P .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :191-200