Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms

被引:75
作者
Kato, N [1 ]
Semba, CP [1 ]
Dake, MD [1 ]
机构
[1] STANFORD UNIV,MED CTR,DIV CARDIOVASC INTERVENT RADIOL,STANFORD,CA 94305
关键词
aneurysm; aortic; therapy; aorta grafts and prostheses;
D O I
10.1016/S1051-0443(96)70852-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Perigraft leak is one of the significant problems associated with transluminal placement of stent-grafts in the treatment of aortic aneurysms, This report describes the authors' experience with transcatheter coil embolization for the treatment of perigraft leaks, MATERIALS AND METHODS: Ten patients who underwent transluminal placement of stent-grafts for the treatment of aortic aneurysms were treated, Al patients had one or more tracts between the aortic wall and stent-graft or between two stent-grafts, resulting in residual aneurysm filling, All tracts were embolized by means of transcatheter deposition of platinum or steel coils, RESULTS: In all patients, all tracts were embolized completely and residual aneurysm filling was eliminated, Complete thrombosis of the aneurysm was confined on follow-up spiral computed tomography in all 10 cases, Two cases required two embolization procedures to completely embolize the tracts, No recurrent leaks or aneurysm expansions were identified on follow-up studies, CONCLUSIONS: Although long-term effectiveness remains to be proved, the initial results with transcatheter coil embolization of tracts are encouraging and suggest this technique is a safe and effective method for the management of perigraft leaks after endovascular placement of stent-grafts.
引用
收藏
页码:805 / 811
页数:7
相关论文
共 19 条
[1]   TRANS-FEMORAL PLACEMENT OF INTRALUMINAL POLYURETHANE PROSTHESIS FOR ABDOMINAL AORTIC-ANEURYSM [J].
BALKO, A ;
PIASECKI, GJ ;
SHAH, DM ;
CARNEY, WI ;
HOPKINS, RW ;
JACKSON, BT .
JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) :305-309
[2]   TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
FIORE, WM ;
DEWEESE, JA ;
QUERAL, LA ;
CRIADO ;
NATH, RL ;
BERKOWITZ, HD ;
SUMPIO, BE .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) :185-197
[3]   PERCUTANEOUS FEMOROPOPLITEAL GRAFT PLACEMENT [J].
CRAGG, AH ;
DAKE, MD .
RADIOLOGY, 1993, 187 (03) :643-648
[4]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[5]  
DONAYRE CE, 1996, PERIPHERAL ENDOVASCU, P364
[6]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[7]  
Guterman L R, 1993, Clin Neurosurg, V40, P56
[8]   INTRALUMINAL BYPASS OF ABDOMINAL AORTIC-ANEURYSM - FEASIBILITY STUDY [J].
LABORDE, JC ;
PARODI, JC ;
CLEM, MF ;
TIO, FO ;
BARONE, HD ;
RIVERA, FJ ;
ENCARNACION, CE ;
PALMAZ, JC .
RADIOLOGY, 1992, 184 (01) :185-190
[9]   PERCUTANEOUS ENDOVASCULAR GRAFT - EXPERIMENTAL EVALUATION [J].
LAWRENCE, DD ;
CHARNSANGAVEJ, C ;
WRIGHT, KC ;
GIANTURCO, C ;
WALLACE, S .
RADIOLOGY, 1987, 163 (02) :357-360
[10]   DELAYED RUPTURE OF AORTIC-ANEURYSMS FOLLOWING ENDOVASCULAR STENT GRAFTING [J].
LUMSDEN, AB ;
ALLEN, RC ;
CHAIKOF, EL ;
RESNIKOFF, M ;
MORITZ, MW ;
GERHARD, H ;
CASTRONUOVO, JJ .
AMERICAN JOURNAL OF SURGERY, 1995, 170 (02) :174-178