Management of Periprosthetic Femur Fractures Treated With Distal Fixation Using a Modular Femoral Stem Using an Anterolateral Approach

被引:63
作者
Park, Myung-Sik [1 ]
Lim, Yung-Jin [1 ]
Chung, Woo-Chul [1 ]
Ham, Dong-Hun [1 ]
Lee, Sang-Hong [2 ]
机构
[1] Chonbuk Natl Univ Hosp, Res Inst Clin Med, Dept Orthoped Surg, Jeonju, South Korea
[2] Chosun Univ Hosp, Dept Orthoped Surg, Kwangju, South Korea
关键词
periprosthetic femoral fractures; modular distal fix femoral stem; revision surgery; TOTAL HIP-ARTHROPLASTY; IPSILATERAL FEMUR; REVISION; SHAFT;
D O I
10.1016/j.arth.2009.07.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The authors retrospectively analyzed 27 hips with periprosthetic femoral fractures (types B2 and 133) treated with distal fixation using a modular, fluted, femoral stem. The average follow-up was 4.8 years. Most fractures (25 hips) were united (92.6%), and mean Harris Hip Score at follow-up was 84.7. Subsidence was noted in 2 patients within 6 months postoperatively, but despite the subsidence, one achieved union. One patient developed peroneal nerve palsy. Two hips were defined as failure: one nonunion associated with infection, and the other one had 10 mm more subsidence. No dislocation occurred in any of the patients. This technique has proven to be reliable in the treatment of difficult fractures in the acute stage, although concerns regarding the subsidence remain when using this femoral stem.
引用
收藏
页码:1270 / 1276
页数:7
相关论文
共 34 条
[1]
FRACTURES OF THE IPSILATERAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
ADOLPHSON, P ;
JONSSON, U ;
KALEN, R .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1987, 106 (06) :353-357
[2]
Beals R K., 1996, Clin. Orthop. Relat. Res, V327, P238, DOI DOI 10.1097/00003086-199606000-00029
[3]
Femoral revision - Distal fixation with fluted, tapered grit-blasted stems [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :142-146
[4]
BETHEA JS, 1982, CLIN ORTHOP RELAT R, P95
[5]
Böhm P, 2001, J BONE JOINT SURG AM, V83A, P1023
[6]
FRACTURES OF THE FEMUR IN RELATION TO CEMENTED HIP PROSTHESES [J].
COOKE, PH ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :386-389
[7]
Dumez JF, 1996, REV CHIR ORTHOP, V82, P225
[8]
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293
[9]
Dysart S H, 1989, J Arthroplasty, V4, P187, DOI 10.1016/S0883-5403(89)80074-9
[10]
Garbuz DS, 1998, AAOS INSTR COURS LEC, V47, P237