Active compression-decompression resuscitation: The influence of different chest geometries on the force transmission

被引:7
作者
Haid, C [1 ]
Rabl, W [1 ]
Baubin, M [1 ]
机构
[1] UNIV INNSBRUCK, DEPT ORTHOPED SURG, BIOMECH LAB, A-6020 INNSBRUCK, AUSTRIA
关键词
cardiopulmonary-resuscitation; suction-device; chest-model; force-distribution;
D O I
10.1016/S0300-9572(97)01104-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Active compression-decompression cardiopulmonary resuscitation (ACD-CPR) is performed using a plunger-like suction device applied onto the chest. Forces are partly transferred through the center of this device as well as through the peripheral ring of the plunger's lip seal. We analysed the load transmission distribution of the Ambu CardioPump(R) therefore a homemade mechanical model was used for simulating different chest geometries. WE applied compression forces up to 750N on the device using a 'material testing machine', and we determined the load transferred through the central part of the device and the peripheral ring respectively. The results show that the deeper the sternum is inbeded in the chest the more force is distributed onto the peripheral ring of the plunger's vacuum cup. For a simulated flat chest, 70 N was transferred through the peripheral ring; at a simulated sternal depression of 20 mm, more than 300 N were transferred peripherally. This study points out that different chest geometries have to be considered when using CardioPump(R). (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:83 / 85
页数:3
相关论文
共 8 条
[1]  
[Anonymous], 1992, Journal of the American Medical Association, DOI [10. 1001/jama. 1992. 03490160041023, DOI 10.1001/JAMA.1992.03490160041023]
[2]   ACTIVE COMPRESSION-DECOMPRESSION CPR IMPROVES VITAL ORGAN PERFUSION IN A DOG-MODEL OF VENTRICULAR-FIBRILLATION [J].
CHANG, MW ;
COFFEEN, P ;
LURIE, KG ;
SHULTZ, J ;
BACHE, RJ ;
WHITE, CW .
CHEST, 1994, 106 (04) :1250-1259
[3]  
COHAN TJ, 1992, AM HEART J, V124, P1145
[4]   STERNAL FORCE-DISPLACEMENT RELATIONSHIP DURING CARDIOPULMONARY-RESUSCITATION [J].
GRUBEN, KG ;
GUERCI, AD ;
HALPERIN, HR ;
POPEL, AS ;
TSITLIK, JE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (02) :195-201
[5]  
GULY UM, 1995, BRIT HEART J, V73, P372
[6]   GUIDELINES FOR BASIC LIFE-SUPPORT [J].
HOLMBERG, S ;
HANDLEY, A ;
BAHR, J ;
BASKETT, P ;
BOSSAERT, L ;
CHAMBERLAIN, D ;
DICK, W ;
VANDRENTH, A ;
EKSTROM, L ;
JUCHEMS, R ;
KETTLER, D ;
MARSDEN, A ;
MOESCHLER, O ;
MONSIEURS, K ;
PETIT, P ;
PRIMOZ, H ;
SCHUTTLER, J .
RESUSCITATION, 1992, 24 (02) :103-110
[7]   EVALUATION OF STANDARD AND ACTIVE COMPRESSION-DECOMPRESSION CPR IN AN ACUTE HUMAN-MODEL OF VENTRICULAR-FIBRILLATION [J].
SHULTZ, JJ ;
COFFEEN, P ;
SWEENEY, M ;
DETLOFF, B ;
KEHLER, C ;
PINEDA, E ;
YAKSHE, P ;
ADLER, SW ;
CHANG, M ;
LURIE, KG .
CIRCULATION, 1994, 89 (02) :684-693
[8]   ACTIVE COMPRESSION-DECOMPRESSION RESUSCITATION - ANALYSIS OF TRANSMITRAL FLOW AND LEFT-VENTRICULAR VOLUME BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN HUMANS [J].
TUCKER, KJ ;
REDBERG, RF ;
SCHILLER, NB ;
COHEN, TJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (05) :1485-1493