Fluorescent determination of chloride in nanoliter samples

被引:30
作者
García, NH [1 ]
Plato, CF [1 ]
Garvin, JL [1 ]
机构
[1] Henry Ford Hosp, Div Hypertens & Vasc Res, Detroit, MI 48202 USA
关键词
cotransport; furosemide; DIDS; bromide; kidney; thick ascending limb;
D O I
10.1046/j.1523-1755.1999.00239.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. Measurements of Cl- in nanoliter samples, such as those collected during isolated, perfused tubule experiments, have been difficult, somewhat insensitive, and/or require custom-made equipment. We developed a technique using a fluorescent Cl- indicator, 6-methoxy N-(3-sulfopropyl) quinolinium (SPQ), to make these measurements simple and reliable. Methods. This is a simple procedure that relies on the selectivity of the dye and the fact that Cl- quenches its fluorescence. To measure millimolar quantities of Cl- in nanoliter samples, we prepared a solution of 0.25 mM SPQ and loaded it into the reservoir of a continuous-flow ultramicrofluorometer, which can be constructed from commercially available components. Samples were injected with a calibrated pipette via an injection port, and the resultant peak fluorescent deflections were recorded. The deflections represent a decrease in fluorescence caused by the quenching effect of the Cl- injected. Results. The method yielded a linear response with Cl- concentrations from 5 to 200 mM NaCl. The minimum detectable Cl- concentration was approximately 5 mM. The coefficient of variation between 5 and 200 mM was 1.7%. Resolution, defined as two times the standard error divided by the slope, between 10 and 50 mM and between 50 and 200 nM was 1 mM and 2.6 mM, respectively. Furosemide, diisothiocyanostilbene-2,2'-disulfonic acid and other nonchloride anions (HEPES, HCO3, SO4, and PO4) did not interfere with the assay, whereas 150 mM NaBr resulted in a peak height greater than 150 NaCl. In addition, the ability to measure Cl- did not vary with pH within the physiological range. Conclusion. We developed an easy, accurate, and sensitive method to measure Cl- concentration in small aqueous solution samples.
引用
收藏
页码:321 / 325
页数:5
相关论文
共 19 条
[1]   GLUCAGON STIMULATES CHLORIDE TRANSPORT INDEPENDENTLY OF CYCLIC-AMP IN THE RAT MEDULLARY TAL [J].
ANDO, Y ;
TABEI, K ;
FURUYA, H ;
ASANO, Y .
KIDNEY INTERNATIONAL, 1989, 36 (05) :760-767
[2]  
FUJIMOTO M, 1976, JPN J PHYSIOL, V26, P631
[3]   ANF AND ANGIOTENSIN-II INTERACT VIA KINASES IN THE PROXIMAL STRAIGHT TUBULE [J].
GARCIA, NH ;
GARVIN, JL .
AMERICAN JOURNAL OF PHYSIOLOGY-RENAL PHYSIOLOGY, 1995, 268 (04) :F730-F735
[4]  
GARCIA NH, 1994, J AM SOC NEPHROL, V5, P1133
[5]  
GARVIN J L, 1988, American Journal of Physiology, V255, pF57
[6]  
GARVIN JL, 1990, J AM SOC NEPHROL, V1, P272
[7]   EFFECT OF BRADYKININ ON NACL TRANSPORT IN THE MEDULLARY THICK ASCENDING LIMB OF THE RAT [J].
GRIDER, J ;
FALCONE, J ;
KILPATRICK, E ;
OTT, C ;
JACKSON, B .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1995, 287 (01) :101-104
[8]  
HAUGLAND R, 1996, HDB FLUORESCENT PROB, P577
[9]   MEMBRANE CHLORIDE TRANSPORT MEASURED USING A CHLORIDE-SENSITIVE FLUORESCENT-PROBE [J].
ILLSLEY, NP ;
VERKMAN, AS .
BIOCHEMISTRY, 1987, 26 (05) :1215-1219
[10]   EFFECTS OF CL- TRANSPORT INHIBITORS ON CL- PERMEABILITY ACROSS HAMSTER ASCENDING THIN LIMB [J].
ISOZAKI, T ;
YOSHITOMI, K ;
IMAI, M .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :F92-F98