A swept-scanning mode for estimation of blood velocity in the microvasculature

被引:68
作者
Kruse, DE
Silverman, RH
Fornaris, RJ
Coleman, DJ
Ferrara, KW
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
[2] Cornell Univ, Coll Med, Dept Ophthalmol, New York, NY 10021 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.738282
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In contrast to previous systems in which an ultrasonic pulse was repeatedly directed to a discrete line of sight, a new method has been developed to continuously scan over a region in order to rapidly assess blood velocities in superficial small blood vessels. Using this technique, which we call swept-scan, a high frequency transducer can rapidly translate across a region of interest, and sensitive maps of blood velocity in small blood vessels can be constructed. This system has been applied to flow mapping in the anterior segment of the eye, which is clinically significant in cases of trauma and glaucoma. No previous imaging technique has been capable of estimating blood velocities within this region in a clinically useful manner. With this new technique, each 2-D scan of the eye can be obtained in an interval on the order of I second, and blood flow through the iris and ciliary body can be detected in vessels as small as 40 microns. A major implication of this new technique is that a wall filter can be applied continuously to the return from all regions, thus eliminating the transient response that occurs along each line of sight in traditional Doppler systems.
引用
收藏
页码:1437 / 1440
页数:4
相关论文
共 13 条
[1]  
COLEMAN DJ, 1992, RADIOL CLIN N AM, V30, P1105
[2]   Assessment of human ocular hemodynamics [J].
Harris, A ;
Kagemann, L ;
Cioffi, GA .
SURVEY OF OPHTHALMOLOGY, 1998, 42 (06) :509-533
[3]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[4]   Eye injuries in athletics and recreation [J].
Napier, SM ;
Baker, RS ;
Sanford, DG ;
Easterbrook, M .
SURVEY OF OPHTHALMOLOGY, 1996, 41 (03) :229-244
[5]  
*NIH, 1998, NIH PUB
[6]  
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287
[7]  
PAVLIN CJ, 1995, CAN J OPHTHALMOL, V30, P225
[8]   CILIARY VASOCONSTRICTION AFTER TOPICAL ADRENERGIC-DRUGS [J].
VANBUSKIRK, EM ;
BACON, DR ;
FAHRENBACH, WH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (05) :511-517
[9]  
VINGER PF, 1981, OPHTHALMOLOGY, V88, P108
[10]   Color Doppler ultrasound imaging of the eye and orbit [J].
Williamson, TH ;
Harris, A .
SURVEY OF OPHTHALMOLOGY, 1996, 40 (04) :255-267