Template images for nonhuman primate neuroimaging: 1. Baboon

被引:77
作者
Black, KJ [1 ]
Snyder, AZ
Koller, JM
Gado, MH
Perlmutter, JS
机构
[1] Washington Univ, Sch Med, Dept Psychiat, St Louis, MO USA
[2] Washington Univ, Sch Med, Dept Neurol & Neurol Surg, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Dept Radiol, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Anat & Neurobiol, St Louis, MO 63110 USA
[5] Washington Univ, Sch Engn, St Louis, MO 63110 USA
关键词
D O I
10.1006/nimg.2001.0752
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Coregistration of functional brain images across many subjects offers several experimental advantages and is widely used for studies in humans. Voxel-based coregistration methods require a high-quality 3-D template image, preferably one that corresponds to a published atlas. Template images are available for human, but we could not find an appropriate template for neuroimaging studies in baboon. Here we describe the formation of a T1-weighted structural MR template image and a PET blood flow template, derived from 9 and 7 baboons, respectively. Custom software aligns individual MR images to the MRI template; human supervision is needed only to initially estimate any gross rotational misalignment. In these aligned individual images, internal subcortical fiducial points correspond closely to a photomicrographic baboon atlas with an average error of 1.53 mm. Cortical test points showed a mean error of 1.99 min compared to the mean location for each point. Alignment of individual PET blood flow images directly to the PET template was compared to a two-step alignment process via each subject's MR image. The two transformations were identical within 0.41 mm, 0.54 degrees, and 1.0% (translation, rotation, and linear stretch; mean). These quantities provide a check on the validity of the alignment software as well as of the template images. The baboon structural AIR and blood flow PET templates are available on the Internet (purl.org/net/kbmd/b2k) and can be used as targets for any image registration software. (C) 2001 Academic Press.
引用
收藏
页码:736 / 743
页数:8
相关论文
共 41 条
  • [1] ANDERSSON JLR, 1995, J NUCL MED, V36, P1307
  • [2] [Anonymous], ATLAS STEREOTAXIQUE
  • [3] [Anonymous], J CEREB BLOOD FLOW M
  • [4] [Anonymous], 1968, STEREOTAXIC ATLAS BR
  • [5] Ashburner J, 1999, HUM BRAIN MAPP, V7, P254, DOI 10.1002/(SICI)1097-0193(1999)7:4<254::AID-HBM4>3.0.CO
  • [6] 2-G
  • [7] Baboon basal ganglia stereotaxy using internal MRI landmarks: Validation and application to PET imaging
    Black, KJ
    Gado, MH
    Videen, TO
    Perlmutter, JS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) : 881 - 886
  • [8] A metric for testing the accuracy of cross-modality image registration: Validation and application
    Black, KJ
    Videen, TO
    Perlmutter, JS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (05) : 855 - 861
  • [9] Dopamine D1 agonist activates temporal lobe structures in primates
    Black, KJ
    Hershey, T
    Gado, MH
    Perlmutter, JS
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2000, 84 (01) : 549 - 557
  • [10] Black KJ, 1997, J NEUROSCI, V17, P3168