Objectives. To evaluate the application of Virtual reality imaging of the bladder (virtual cystoscopy) in the detection of bladder masses. Methods. Six patients (mean age 61 years, range 43 to 75) with hematuria and positive findings on conventional cystoscopy were studied by means of thin-section helical computed tomography of the air-distended bladder. Using volume-rendering algorithms, interactive intraluminal views of the bladder mucosa were generated (virtual cystoscopy). Results of virtual cystoscopy were compared with those of conventional cystoscopy in each case. Results. Twenty-six (100%) of 26 masses (mean size 1.7 cm, range 0.3 to 6), detected on conventional cystoscopy, were visualized on virtual cystoscopy. Twelve of 26 masses measured less than 1 cm in maximum diameter. All masses were pathologically proven transitional cell carcinomas. Virtual cystoscopy was well tolerated by all patients, and no complications occurred. Conclusions. Our results indicate that virtual cystoscopy is an accurate technique for detection of intrinsic bladder masses. It may represent a radiologic adjunct to conventional cystoscopy for initial evaluation of patients with hematuria and for surveillance of patients after bladder tumor resection. (C) 1997, Elsevier Science Inc. All rights reserved.
引用
收藏
页码:685 / 688
页数:4
相关论文
共 7 条
[1]   Colorectal polyp detection with CT colography: Two- versus three-dimensional techniques - Work in progress [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ehman, RL ;
Ilstrup, DM .
RADIOLOGY, 1996, 200 (01) :49-54
[2]   Three-dimensional CT: Real-time interactive volume rendering [J].
Johnson, PT ;
Heath, DG ;
Bliss, DF ;
Cabral, B ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) :581-583
[3]   Three-dimensional helical CT of the tracheobronchial tree: Evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic correlation [J].
Kauczor, HU ;
Wolcke, B ;
Fischer, B ;
Mildenberger, P ;
Lorenz, J ;
Thelen, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :419-424
[4]  
Larijani L., 1994, VIRTUAL REALITY PRIM
[5]   The bladder and bladder tumors: Imaging with three dimensional display of helical CT data [J].
Narumi, Y ;
Kumatani, T ;
Sawai, Y ;
Kuriyama, K ;
Kuroda, C ;
Takahashi, S ;
Kim, T ;
Tsuda, K ;
Murakami, T ;
Nakamura, H .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) :1134-1135
[6]   Virtual endoscopy: Is it reality? [J].
Vining, DJ .
RADIOLOGY, 1996, 200 (01) :30-31
[7]   CT cystoscopy: An innovation in bladder imaging [J].
Vining, DJ ;
Zagoria, RJ ;
Liu, K ;
Stelts, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) :409-410