Antibody binding to a functionalized supported lipid layer: A direct acoustic immunosensor

被引:82
作者
Gizeli, E [1 ]
Liley, M [1 ]
Lowe, CR [1 ]
Vogel, H [1 ]
机构
[1] SWISS FED INST TECHNOL, LAB CHIM PHYS POLYMERES & MEMBRANES, CH-1015 LAUSANNE, SWITZERLAND
关键词
D O I
10.1021/ac970519m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct immunosensor has been developed using an acoustic wave device as a transducer. The device is based on an acoustic waveguide geometry that supports a Love wave, The biorecognition surface, formed on a gold layer, consisted of a biotinylated supported lipid layer which specifically bound streptavidin and, subsequently, biotinylated goat IgG, The modified surface was used as a model immunosensor and successfully detected rabbit anti-goat IgG in the concentration range 3 x 10(-8)-10(-6) M, Using the anti-goat IgG binding isotherm and the time-resolved measurements of antibody binding, both the binding and rate constants of the reaction were determined, The specificity of each binding step was studied with the acoustic wave device, and it was concluded that the phospholipid bilayer showed a good suppression of nonspecific binding, Comparative measurements using surface plasmon resonance allowed the response of the immunosensor to be quantitatively correlated with mass binding to the surface.
引用
收藏
页码:4808 / 4813
页数:6
相关论文
共 28 条
  • [1] IMMUNOSENSORS FOR CLINICAL ANALYSIS
    AIZAWA, M
    [J]. ADVANCES IN CLINICAL CHEMISTRY, VOL 31, 1994, 31 : 247 - 275
  • [2] ACOUSTIC-WAVE BIOSENSORS
    ANDLE, JC
    VETELINO, JF
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1994, 44 (03) : 167 - 176
  • [3] FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD
    BAIN, CD
    TROUGHTON, EB
    TAO, YT
    EVALL, J
    WHITESIDES, GM
    NUZZO, RG
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) : 321 - 335
  • [4] THE RESONANT MIRROR - A NOVEL OPTICAL SENSOR FOR DIRECT SENSING OF BIOMOLECULAR INTERACTIONS .2. APPLICATIONS
    BUCKLE, PE
    DAVIES, RJ
    KINNING, T
    YEUNG, D
    EDWARDS, PR
    POLLARDKNIGHT, D
    LOWE, CR
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (7-8) : 355 - 363
  • [5] BIOMEMBRANES AND NEW HEMOCOMPATIBLE MATERIALS
    CHAPMAN, D
    [J]. LANGMUIR, 1993, 9 (01) : 39 - 45
  • [6] DAHINT R, 1994, J ANAL CHEM+, V18, P2888
  • [7] A study of love-wave acoustic sensors
    Du, J
    Harding, GL
    Ogilvy, JA
    Dencher, PR
    Lake, M
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1996, 56 (03) : 211 - 219
  • [8] Surface engineering: Optimization of antigen presentation in self-assembled monolayers
    Duschl, C
    SevinLandais, AF
    Vogel, H
    [J]. BIOPHYSICAL JOURNAL, 1996, 70 (04) : 1985 - 1995
  • [9] BIOLOGICALLY ADDRESSABLE MONOLAYER STRUCTURES FORMED BY TEMPLATES OF SULFUR-BEARING MOLECULES
    DUSCHL, C
    LILEY, M
    CORRADIN, G
    VOGEL, H
    [J]. BIOPHYSICAL JOURNAL, 1994, 67 (03) : 1229 - 1237
  • [10] FEIJTER JA, 1978, BIOPOLYMERS, V17, P1759