Protein microarrays enhanced performance using nanobeads arraying and polymer coating

被引:23
作者
Marquette, C. A.
Cretich, M.
Blum, L. J.
Chiari, M.
机构
[1] Univ Lyon 1, CNRS, UMR 5013, Lab Genie Enzymat & Biomol, F-69622 Villeurbanne, France
[2] CNR, Ist Chim Riconoscimento Mol, I-20131 Milan, Italy
关键词
biochip; chemi luminescence; microarray; PDMS; rheumatoid factor;
D O I
10.1016/j.talanta.2006.06.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nanosize material composed of 330 nm glass beads coated with a copolymer of N,N-dimethylacrylamide (DMA), N,N-acryloyloxysuccinimide (NAS) and [3-(methacryloyl-oxy)propyl]trimethoxysilane (MAPS) was developed to improve the protein immobilization on biochips. The developed material, bearing rabbit-IgG proteins, was arrayed as 150 mu m spots trapped at the surface of a poly(dimethylsiloxane) elastomer (PDMS), and compared to copoly(DMA-NAS-MAPS)-coated glass slides and latex beads based biochips. Evidences were made through scanning electron microscopy that the newly developed material based microarray exhibited surface irregularities at the submicron level leading to high specific area. The combination of such large immobilization area with the highly efficient protein immobilization of the copoly(DMA-NAS-MAPS) polymer, enabled the achievement of microarrays exhibiting good performances both in pure media and complex samples (human sera). Indeed, high specific/non-specific signal ratio was found using this optimized immobilization procedure. Chemiluminescent detection of anti-rabbit-IgG was obtained through peroxidase labeled antibodies in the 5 mu g/l to 10 mg/l range. Application of the developed system to real samples was achieved for the detection of rheumatoid factor (RF) through a capture assay. Interesting results were obtained, with a RF detection over the 5.3-485 IU/ml range and without measurable matrix effect or non-specific signal. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1312 / 1318
页数:7
相关论文
共 24 条
[1]   Protein biochips: the quiet before the storm [J].
Bodovitz, S ;
Joos, T ;
Bachmann, J .
DRUG DISCOVERY TODAY, 2005, 10 (04) :283-287
[2]   Functional protein microarrays for parallel characterisation of p53 mutants [J].
Boutell, JM ;
Hart, DJ ;
Godber, BLJ ;
Kozlowski, RZ ;
Blackburn, JM .
PROTEOMICS, 2004, 4 (07) :1950-1958
[3]   Solid supports in enzyme-linked immunosorbent assay and other solid-phase immunoassays [J].
Butler, JE .
METHODS-A COMPANION TO METHODS IN ENZYMOLOGY, 2000, 22 (01) :4-23
[4]  
Cathcart ES, 1975, RHEUMATOID FACTORS L
[5]   Peptide microarrays for the characterization of antigenic regions of human chromogranin A [J].
Chiari, M ;
Cretich, M ;
Corti, A ;
Damin, F ;
Pirri, G ;
Longhi, R .
PROTEOMICS, 2005, 5 (14) :3600-3603
[6]   A new polymeric coating for protein microarrays [J].
Cretich, M ;
Pirri, G ;
Damin, F ;
Solinas, I ;
Chiari, M .
ANALYTICAL BIOCHEMISTRY, 2004, 332 (01) :67-74
[7]   A quantitative protein interaction network for the ErbB receptors using protein microarrays [J].
Jones, RB ;
Gordus, A ;
Krall, JA ;
MacBeath, G .
NATURE, 2006, 439 (7073) :168-174
[8]   Solid supports for microarray immunoassays [J].
Kusnezow, W ;
Hoheisel, JD .
JOURNAL OF MOLECULAR RECOGNITION, 2003, 16 (04) :165-176
[9]   Protein microarrays as tools for functional proteomics [J].
LaBaer, J ;
Ramachandran, N .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2005, 9 (01) :14-19
[10]   Protein chips: from concept to practice [J].
Lee, YS ;
Mrksich, M .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (12) :S14-S18