A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood

被引:105
作者
Chen, JC [1 ]
Chung, HH [1 ]
Hsu, CT [1 ]
Tsai, DM [1 ]
Kumar, AS [1 ]
Zen, JM [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
screen-printed electrode; single-use electrochemical sensors; uric acid; whole blood; electrochemical test strip;
D O I
10.1016/j.snb.2005.02.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report here a non-enzymatic detecting electrode strip for fast monitoring of uric acid in human whole blood. A single-use amperometric uric acid sensor strip, incorporating a three-electrode configuration, has been fabricated on a polypropylene substrate using low cost screen-printing (thick-film) technology. Both the working and counter electrodes were prepared by screen-printing commercial carbon ink. The integration on the same support of pseudo-reference electrode was obtained by screen-printing a commercial silver ink and subsequent electrochemical pretreatment. Simply by placing a 20 mu l human whole blood drop on the strip is enough for uric acid analysis by square-wave voltammetry. Real human whole blood samples were analyzed by this method and compared to the phosphotungstic acid clinical test procedure with satisfactory results. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:364 / 369
页数:6
相关论文
共 31 条
[1]   Uric acid: role in cardiovascular disease and effects of losartan [J].
Alderman, M ;
Aiyer, KJV .
CURRENT MEDICAL RESEARCH AND OPINION, 2004, 20 (03) :369-379
[2]  
[Anonymous], 1996, LAB TEST HDB
[3]   AN IMPROVED VOLTAMMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF URIC-ACID WITH ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODES [J].
CAI, XH ;
KALCHER, K ;
NEUHOLD, C ;
OGOREVC, B .
TALANTA, 1994, 41 (03) :407-413
[4]   Glucose biosensor strip in a three electrode configuration based on composite and biocomposite materials applied by planar thick film technology [J].
Galán-Vidal, C ;
Muñoz, J ;
Domínguez, C ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 52 (03) :257-263
[5]   Direct determination of uric acid in serum by a fluorometric-enzymatic method based on uricase [J].
Galbán, J ;
Andreu, Y ;
Almenara, MJ ;
de Marcos, S ;
Castillo, JR .
TALANTA, 2001, 54 (05) :847-854
[6]  
GEISINGER KR, 1979, AM J CLIN PATHOL, V72, P330
[7]   VOLTAMMETRIC AND AMPEROMETRIC BEHAVIOR OF URIC-ACID AT BARE AND SURFACE-MODIFIED SCREEN-PRINTED ELECTRODES - STUDIES TOWARDS A DISPOSABLE URIC-ACID SENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1992, 117 (08) :1299-1303
[8]   NOVEL, REAGENTLESS, AMPEROMETRIC BIOSENSOR FOR URIC-ACID BASED ON A CHEMICALLY-MODIFIED SCREEN-PRINTED CARBON ELECTRODE COATED WITH CELLULOSE-ACETATE AND URICASE [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (05) :833-840
[9]  
Hsieh Chun-Lung S.Y.-S., 2001, Non-enzymatic Disposable Uric Acid Detecting Electrode Strip, Method for Producing the Same and its Use, Patent No. [US6258230B1, 6258230]
[10]   Is there a pathogenetic role for uric acid in hypertension and cardiovascular and renal disease? [J].
Johnson, RJ ;
Kang, DH ;
Feig, D ;
Kivlighn, S ;
Kanellis, J ;
Watanabe, S ;
Tuttle, KR ;
Rodriguez-Iturbe, B ;
Herrera-Acosta, J ;
Mazzali, M .
HYPERTENSION, 2003, 41 (06) :1183-1190