Source apportionment of volatile organic compounds in Hong Kong homes

被引:72
作者
Guo, H. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Volatile organic compounds; PCA/APCS; Source apportionment; Hong Kong; POLYCYCLIC AROMATIC-HYDROCARBONS; INDOOR ENVIRONMENTS; RECEPTOR MODELS; AIR-POLLUTANTS; URBAN; EXPOSURE; FORMALDEHYDE; OUTDOOR; CHINA; VOCS;
D O I
10.1016/j.buildenv.2011.05.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor volatile organic compound (VOC) data obtained in 100 Hong Kong homes were analyzed to investigate the nature of emission sources and their contributions to indoor concentrations. A principal component analysis (PCA) showed that off-gassing of building materials, household products, painted wood products, room freshener, mothballs and consumer products were the major sources of VOCs in Hong Kong homes. The source apportionments were then evaluated by using an absolute principal component scores (APCS) technique combined with multiple linear regressions. The results indicated that 76.5 +/- 1% (average +/- standard error) of the total VOC emissions in Hong Kong homes attributes to the off-gassing of building materials, followed by the room freshener (8 +/- 4%), household products (6 +/- 2%), mothballs (5 +/- 3%) and painted wood products (4 +/- 2%). Analysis on the source strength in the monitored homes revealed that although six indoor sources were identified and quantified in the Hong Kong homes, only some homes were responsible for the elevated concentrations of target VOCs emitted from these sources. The findings provide us the mechanism of reducing levels of indoor VOCs and ultimately lead to cost effective reduction in population exposures. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2280 / 2286
页数:7
相关论文
共 50 条
[1]   Characterisation of NMHCs in a French urban atmosphere: overview of the main sources [J].
Borbon, A ;
Locoge, N ;
Veillerot, M ;
Galloo, JC ;
Guillermo, R .
SCIENCE OF THE TOTAL ENVIRONMENT, 2002, 292 (03) :177-191
[2]   EFFECTS OF LOW AMBIENT LEVELS OF OZONE AND SULFATES ON THE FREQUENCY OF RESPIRATORY ADMISSIONS TO ONTARIO HOSPITALS [J].
BURNETT, RT ;
DALES, RE ;
RAIZENNE, ME ;
KREWSKI, D ;
SUMMERS, PW ;
ROBERTS, GR ;
RAADYOUNG, M ;
DANN, T ;
BROOK, J .
ENVIRONMENTAL RESEARCH, 1994, 65 (02) :172-194
[3]  
CHAN KJK, 2000, J BUILDING SURVEYING, V2, P27
[4]   Volatile acetic acid and formaldehyde emission from plywood treated with boron compound [J].
Colak, S ;
Colakoglu, G .
BUILDING AND ENVIRONMENT, 2004, 39 (05) :533-536
[5]  
CRUMP D, 1998, ENCY OCCUPATIONAL HL, V2
[6]   VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland [J].
Edwards, RD ;
Jurvelin, J ;
Koistinen, K ;
Saarela, K ;
Jantunen, M .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (28) :4829-4841
[7]   Tropospheric air pollution: Ozone, airborne toxics, polycyclic aromatic hydrocarbons, and particles [J].
FinlaysonPitts, BJ ;
Pitts, JN .
SCIENCE, 1997, 276 (5315) :1045-1052
[8]   Variability of personal chemical exposure in eight offfice buildings in Sweden [J].
Glas, B ;
Levin, JO ;
Stenberg, B ;
Stenlund, H ;
Sunesson, AL .
JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 2004, 14 (Suppl 1) :S49-S57
[9]  
GLAZER JA, 1981, ENVIRON SCI TECHNOL, V15, P1426
[10]  
GODISH T, 2004, AIR QUALITY, P4