Organ doses to adult patients for chest CT

被引:47
作者
Huda, Walter [1 ]
Sterzik, Alexander [1 ]
Tipnis, Sameer [1 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
computerised tomography; dosimetry; liver; lung; COMPUTED-TOMOGRAPHY EXAMINATIONS; TUBE-CURRENT MODULATION; PEDIATRIC-PATIENTS; QUALITY; PROGRAM; INDEX; SIZE; KVP;
D O I
10.1118/1.3298015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Methods: A CT dosimetry spreadsheet (ImPACT CT patient dosimetry calculator) was used to compute organ doses for a 70 kg patient undergoing chest CT examinations, as well as volume computed tomography dose index (CTDI(vol)) in a body CT dosimetry phantom at the same CT technique factors. Ratios of organ dose to CTDI(vol) (f(organ)) were generated as a function of anatomical location in the chest for the breasts, lungs, stomach, red bone marrow, liver, thyroid, liver, and thymus. Values of f(organ) were obtained for x-ray tube voltages ranging from 80 to 140 kV for 1, 4, 16, and 64 slice CT scanners from two vendors. For constant CT techniques, we computed ratios of dose in water phantoms of differing diameter. By modeling patients of different weights as equivalent water cylinders of different diameters, we generated factors that permit the estimation of the organ doses in patients weighing between 50 and 100 kg who undergo chest CT examinations relative to the corresponding organ doses received by a 70 kg adult. Results: For a 32 cm long CT scan encompassing the complete lungs, values of f(organ) ranged from 1.7 (thymus) to 0.3 (stomach). Organs that are directly in the x-ray beam, and are completely irradiated, generally had f(organ) values well above 1 (i.e., breast, lung, heart, and thymus). Organs that are not completely irradiated in a total chest CT scan generally had f(organ) values that are less than 1 (e.g., red bone marrow, liver, and stomach). Increasing the x-ray tube voltage from 80 to 140 kV resulted in modest increases in f(organ) for the heart (9%) and thymus (8%), but resulted in larger increases for the breast (19%) and red bone marrow (21%). Adult patient chests have been modeled by water cylinders with diameters between similar to 20 cm for a 50 kg patient and similar to 28 cm for a 100 kg patient. At constant x-ray techniques, a 50 kg patient is expected to have doses that are similar to 18% higher than those in a 70 kg adult, whereas a 100 kg patient will have doses that are similar to 18% lower. Conclusions: We describe a practical method to use CTDI data provided by commercial CT scanners to obtain patient and examination specific estimates of organ dose for chest CT examinations.
引用
收藏
页码:842 / 847
页数:6
相关论文
共 22 条
[1]
Automatic tube-current modulation in CT -: A comparison between different solutions [J].
Althén, JN .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :308-312
[2]
Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT [J].
Angel, Erin ;
Yaghmai, Nazanin ;
Jude, Cecilia Matilda ;
DeMarco, John J. ;
Cagnon, Christopher H. ;
Goldin, Jonathan G. ;
Primak, Andrew N. ;
Stevens, Donna M. ;
Cody, Dianna D. ;
McCollough, Cynthia H. ;
McNitt-Gray, Michael F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03) :497-511
[3]
It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization [J].
Brenner, DJ ;
McCollough, CH ;
Orton, CG .
MEDICAL PHYSICS, 2006, 33 (05) :1189-1191
[4]
Patient size and x-ray technique factors in head computed tomography examinations. II. Image quality [J].
Huda, W ;
Lieberman, KA ;
Chang, J ;
Roskopf, ML .
MEDICAL PHYSICS, 2004, 31 (03) :595-601
[5]
Effective doses to patients undergoing thoracic computed tomography examinations [J].
Huda, W ;
Scalzetti, EM ;
Roskopf, M .
MEDICAL PHYSICS, 2000, 27 (05) :838-844
[6]
An approach for the estimation of effective radiation dose at CT in pediatric patients [J].
Huda, W ;
Atherton, JV ;
Ware, DE ;
Cumming, WA .
RADIOLOGY, 1997, 203 (02) :417-422
[7]
Converting dose-length product to effective dose at CT [J].
Huda, Walter ;
Ogden, Kent M. ;
Khorasani, Mohammad R. .
RADIOLOGY, 2008, 248 (03) :995-1003
[8]
ICRP, 2000, MANAGING PATIENT DOS, VVolume 30
[9]
*IEC, 2003, 60601244 IEC
[10]
International Commission on Radiation Protection, 2007, ANN ICRP, V37