摘要
This paper deals with a preprocessing technique of magnetic resonance angiography (MRA) images, applied before maximum-intensity-projection (MIP). The purpose was to recover small low-intensity vessels, visible in individual slices, but lost in MIP images that usually have higher background level than the individual slices. The authors have developed a nonlinear three-dimensional spatial filtering technique (called HD filter) based on anisotropic smoothing. The filter first searches for the local orientation of the vessel. It then performs a nonlinear smoothing in the vessel's local direction so as to avoid blurring its boundaries. Noise level reduction, contrast enhancement, and improved small vessel visibility achieved by this filter are illustrated on dynamic contrast-enhanced subtraction MRA images of the lower limbs.
引用
收藏
页码:914 / 919
页数:6
相关论文
共 14 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]  
Anderson Charles M., 1993, P83
[3]   ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS [J].
ANDERSON, CM ;
SALONER, D ;
TSURUDA, JS ;
SHAPEERO, LG ;
LEE, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) :623-629
[4]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[5]  
CHAMPIN O, 1996, THESIS U C BERNARD L
[6]   AN ALGORITHM FOR MR-ANGIOGRAPHY IMAGE-ENHANCEMENT [J].
CHEN, HG ;
HALE, J .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :534-540
[7]   VOLUME RENDERING AND CONNECTIVITY ALGORITHMS FOR MR ANGIOGRAPHY [J].
CLINE, HE ;
DUMOULIN, CL ;
LORENSEN, WE ;
SOUZA, SP ;
ADAMS, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :384-394
[8]  
CZERWINSKI RN, P IEEE ULTR S BALT 1, P951
[9]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[10]   VESSEL ENHANCEMENT FILTERING IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YP ;
PARKER, DL ;
DAVIS, WL .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (02) :151-157