Validation of the Welch Allyn QuietTrak ambulatory blood pressure monitor in pregnancy

被引:12
作者
Penny, JA
Shennan, AH
Rushbrook, J
Halligan, AW
Taylor, DJ
deSwiet, M
机构
[1] QUEEN CHARLOTTES MATERN HOSP,LONDON,ENGLAND
[2] LEICESTER ROYAL INFIRM,LEICESTER,LEICS,ENGLAND
关键词
ambulatory blood pressure monitor; blood pressure determination; pregnancy; validation; Welch Allyn QuietTrak;
D O I
10.3109/10641959609009592
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of the Welch Allyn QuietTrak ambulatory blood pressure monitor in pregnancy. Method: The QuietTrak ambulatory blood pressure monitor was validated for accuracy using the protocol of the British Hypertension Society (BHS). Results: The machine achieved a grade B for systolic and diastolic blood pressure according to the BHS grading criteria. The mean difference (standard deviation) between observer and machine for systolic was 0.34 mm Hg (9 mm Hg) and for diastolic was -1.6 mm Hg (8 mm Hg). Conclusions: The Welch Allyn QuietTrak ambulatory blood pressure monitor is accurate for use in pregnancy according to BHS and narrowly failed the criteria of the Association for the Advancement of Medical Instrumentation (AAMI) criteria.
引用
收藏
页码:313 / 321
页数:9
相关论文
共 16 条
[1]  
[Anonymous], AM J OBSTET GYNECOL
[2]   MEASURING BLOOD-PRESSURE IN PREGNANT-WOMEN - A COMPARISON OF DIRECT AND INDIRECT METHODS [J].
BROWN, MA ;
REITER, L ;
SMITH, B ;
BUDDLE, ML ;
MORRIS, R ;
WHITWORTH, JA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) :661-667
[3]  
CLARK S, 1991, OBSTET GYNECOL, V77, P152
[4]   VALIDATION OF AUTOMATED BLOOD-PRESSURE RECORDING IN PREGNANCY [J].
FRANX, A ;
VANDERPOST, JAM ;
ELFERING, IM ;
VEERMAN, DP ;
MERKUS, HMWM ;
BOER, K ;
VANMONTFRANS, GA .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (01) :66-69
[5]   INDIRECT BLOOD-PRESSURE MEASUREMENT IN PREGNANCY - KOROTKOFF PHASE 4 VERSUS PHASE 5 [J].
JOHENNING, AR ;
BARRON, WM .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (03) :577-580
[6]  
O'Shea J. C., 1994, American Journal of Hypertension, V7, p118A
[7]   AN OUTLINE OF THE REVISED BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
ALTMAN, DG ;
BLAND, M ;
COATS, A ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1993, 11 (06) :677-679
[8]  
OBRIEN E, 1993, J HYPERTENS, V11, pS282
[9]   COMPARATIVE ACCURACY OF 6 AMBULATORY DEVICES ACCORDING TO BLOOD-PRESSURE LEVELS [J].
OBRIEN, E ;
ATKINS, N ;
MEE, F ;
OMALLEY, K .
JOURNAL OF HYPERTENSION, 1993, 11 (06) :673-675
[10]   RECORDING DIASTOLIC BLOOD-PRESSURE IN PREGNANCY [J].
PERRY, IJ ;
STEWART, BA ;
BROCKWELL, J ;
KHAN, M ;
DAVIES, P ;
BEEVERS, DG ;
LUESLEY, DM .
BRITISH MEDICAL JOURNAL, 1990, 301 (6762) :1198-1198