Short-wavelength acuity: optical factors affecting detection and resolution of blue-yellow sinusoidal gratings in foveal and peripheral vision

被引:17
作者
Anderson, RS [1 ]
Coulter, E
Zlatkova, MB
Demirel, S
机构
[1] Univ Ulster, Sch Biomed Sci, Vis Sci Res Grp, Coleraine BT52 1SA, Londonderry, North Ireland
[2] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
基金
英国生物技术与生命科学研究理事会;
关键词
peripheral vision; acuity; colour vision; defocus;
D O I
10.1016/S0042-6989(02)00410-8
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Previous studies have indicated that peripheral achromatic grating resolution is limited by the sampling density of the neural array (sampling limited), and largely unaffected by large amounts of optical defocus and significant changes in luminance. Under certain conditions, peripheral short-wavelength sensitive (SWS) grating acuity is also sampling limited. We wished to determine how the sampling-limited nature of SWS-driven grating resolution was affected by changing optical defocus and stimulus luminance. Using SWS-cone isolation techniques, detection and resolution acuity were I measured for sinusoidal gratings under varying levels of stimulus mean luminance and optical defocus in the fovea and at 20degrees eccentricity. From 1.4 down to 0.3 cd/m(2) peripheral detection acuity was superior to resolution acuity, accompanied by observations of aliasing: there was little change in resolution performance throughout this range. For defocus up to 3-4 dioptres, peripheral detection acuity was superior to resolution but fell steadily: resolution performance remained flat throughout the same range. Unlike achromatic acuity, foveal resolution performance displayed some robustness to defocus but to a lesser degree than the periphery. Peripheral SWS-driven resolution remains sampling limited for large changes in stimulus luminance and optical defocus, and,should thus be useful as a clinical test of SWS-driven ganglion cell density. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 41 条
[1]   The selective effect of optical defocus on detection and resolution acuity in peripheral vision [J].
Anderson, RS .
CURRENT EYE RESEARCH, 1996, 15 (03) :351-353
[2]   Aliasing in peripheral vision for counterphase gratings [J].
Anderson, RS .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (11) :2288-2293
[3]   Peripheral resolution using stationary and flickering gratings: the effects of age [J].
Anderson, RS ;
McDowell, DR .
CURRENT EYE RESEARCH, 1997, 16 (12) :1209-1214
[4]   PSYCHOPHYSICAL LOCALIZATION OF THE HUMAN VISUAL STREAK [J].
ANDERSON, RS ;
WILKINSON, MO ;
THIBOS, LN .
OPTOMETRY AND VISION SCIENCE, 1992, 69 (03) :171-174
[5]   Effect of window size on detection acuity and resolution acuity for sinusoidal gratings in central and peripheral vision [J].
Anderson, RS ;
Evans, DW ;
Thibos, LN .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (04) :697-706
[6]   What limits detection and resolution of short-wavelength sinusoidal gratings across the retina? [J].
Anderson, RS ;
Zlatkova, MB ;
Demirel, S .
VISION RESEARCH, 2002, 42 (08) :981-990
[7]   Psychophysical evidence for a selective loss of M ganglion cells in glaucoma [J].
Anderson, RS ;
OBrien, C .
VISION RESEARCH, 1997, 37 (08) :1079-1083
[8]   Effect of localized defocus on detection thresholds for different sized targets in the fovea and periphery [J].
Anderson, RS ;
McDowell, RD ;
Ennis, FA .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (01) :60-63
[9]  
ANDERSON S J, 1990, Investigative Ophthalmology and Visual Science, V31, P495
[10]   POST-RECEPTORAL UNDERSAMPLING IN NORMAL HUMAN PERIPHERAL-VISION [J].
ANDERSON, SJ ;
HESS, RF .
VISION RESEARCH, 1990, 30 (10) :1507-1515