Measurement of extracellular fluid volume in the neonate using multiple frequency bio-impedance analysis

被引:30
作者
Lingwood, BE
Coghlan, JP
Ward, LC
Charles, BG
Colditz, PB
机构
[1] Univ Queensland, Perinatal Res Ctr, Brisbane, Qld, Australia
[2] Univ Queensland, Dept Biochem, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Pharm, Brisbane, Qld, Australia
关键词
bioelectrical impedance; extracellular fluid volume; neonate;
D O I
10.1088/0967-3334/21/2/305
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bioelectrical impedance analysis may be useful for cot-side monitoring of fluid balance in the neonatal intensive care unit (NICU). However the presence of cardio-respiratory monitoring equipment, non-ideal electrode placement and inability to obtain accurate crown-heel measurements may interfere with the ability to obtain reliable impedance data in this setting. This study aimed to investigate the effects of these factors on impedance analysis and to develop a prediction equation for extracellular fluid volume in the neonate. The study found that cardiorespiratory monitoring had no significant effect on multi-frequency impedance measurements. Placement of current delivering electrodes on the ventral rather than dorsal surfaces improved separation of current and voltage electrodes but did not alter impedance results. Contralateral measurements were not significantly different to ipsilateral measurements. In 24 infants, extracellular fluid volume was measured using corrected bromide space (CBS) and simultaneous impedance analysis was performed. There was good correlation between CBS and the impedance quotient F-2/R-0 where F is foot length and R-0 is resistance at zero frequency. The study concludes that despite many potential difficulties associated with impedance analysis in the NICU, reliable measurements of impedance can be obtained and further work to validate prediction equations for ECF is warranted.
引用
收藏
页码:251 / 262
页数:12
相关论文
共 30 条
[1]  
[Anonymous], 2007, Biostatistical analysis
[2]   Sources of error in bioimpedance spectroscopy [J].
Bolton, MP ;
Ward, LC ;
Khan, A ;
Campbell, I ;
Nightingale, P ;
Dewit, O ;
Elia, M .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) :235-245
[3]   Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans [J].
Bracco, D ;
Thiebaud, D ;
Chiolero, RL ;
Landry, M ;
Burckhardt, P ;
Schutz, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (06) :2580-2587
[4]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[5]  
Cornish BH, 1996, EUR J CLIN NUTR, V50, P159
[6]   IMPROVED PREDICTION OF EXTRACELLULAR AND TOTAL-BODY WATER USING IMPEDANCE LOCI GENERATED BY MULTIPLE FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
CORNISH, BH ;
THOMAS, BJ ;
WARD, LC .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (03) :337-346
[7]   THE PREDICTION OF TOTAL-BODY WATER USING BIOELECTRICAL IMPEDANCE IN CHILDREN AND ADOLESCENTS [J].
DAVIES, PSW ;
PREECE, MA ;
HICKS, CJ ;
HALLIDAY, D .
ANNALS OF HUMAN BIOLOGY, 1988, 15 (03) :237-240
[8]   Predicting body cell mass with bioimpedance by using theoretical methods: A technological review [J].
DeLorenzo, A ;
Andreoli, A ;
Matthie, J ;
Withers, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (05) :1542-1558
[9]  
DESHPANDE S, 1998, P NEON SOC RENN
[10]   TOTAL-BODY WATER MEASURED BY O-18 DILUTION AND BIOELECTRICAL IMPEDANCE IN WELL AND MALNOURISHED CHILDREN [J].
FJELD, CR ;
FREUNDTTHURNE, J ;
SCHOELLER, DA .
PEDIATRIC RESEARCH, 1990, 27 (01) :98-102