Application of interhemispheric index for transcranial Doppler sonography velocity measurements and evaluation of recording time

被引:26
作者
BayHansen, J
Ravn, T
Knudsen, GM
机构
[1] Department of Neurology, University Hospital, Rigshospitalet, Copenhagen
[2] Department of Neurology, N2082, Rigshospitalet, 2100 Copenhagen
关键词
blood flow velocity; middle cerebral artery; observer variation; transcranial Doppler;
D O I
10.1161/01.STR.28.5.1009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background nod Purpose To validate the reliability of transcranial Doppler sonography velocity measurements in clinical settings, assessment of the reproducibility of repeated bilateral simultaneous measurements and the optimal recording time is needed. Our hypothesis was that interhemispheric indices would prove more valid than the absolute Velocity measurements usually applied. The potential interference between ultrasound beams in bilateral samplings also needs evaluation. Methods Thirty healthy volunteers were studied at rest within hours or with a 2-month interval between measurements. Absolute blood flow velocities and side-to-side indices between velocities obtained in the middle cerebral arteries were measured over a 30-second period by two independent examiners. The correlation coefficient (r) and the coefficients of variation of the difference between either absolute velocities (CV) or indices (CVi) were calculated. The beat-to-beat variation of the diastolic, systolic, and mean velocities was also recorded. For evaluation of ultrasound beam interference, measurements were performed with and without one probe unplugged. Results In the interobserver study in which measurements were repeated within hours, r=.92, CV=8.8%, and CVi=4.1%. In the intraobserver study in which measurements were repeated with a 2-month interval, r=.8, CV=13.0%, and CVi=7.3%. A recording time of 30 seconds reduced CVi to 2.6%, whereas for absolute velocities 5-second recordings produced an acceptable variation. There was no significant interference between bilaterally placed probes. Conclusions The introduction of interhemispheric indices improves interobserver and intraobserver reproducibility by approximately 50%. We recommend use of the index in clinical settings in which unilateral velocity changes are expected. For measurement of an interhemispheric index, a recording time of 30 seconds is recommended, whereas 5-second measurement periods yield a sufficient estimate of absolute velocities.
引用
收藏
页码:1009 / 1014
页数:6
相关论文
共 16 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   A VALIDATION-STUDY ON THE INTRAOBSERVER REPRODUCTIBILITY OF TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY VELOCITY-MEASUREMENTS [J].
BAUMGARTNER, RW ;
MATHIS, J ;
STURZENEGGER, M ;
MATTLE, HP .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03) :233-237
[3]   TRANSCRANIAL DOPPLER MEASUREMENTS OF THE MIDDLE CEREBRAL-ARTERY - EFFECT OF HEMATOCRIT [J].
BRASS, LM ;
PAVLAKIS, SG ;
DEVIVO, D ;
PIOMELLI, S ;
MOHR, JP .
STROKE, 1988, 19 (12) :1466-1469
[4]   REPEATABILITY OF TRANSCRANIAL DOPPLER MEASUREMENTS OF ARTERIAL BLOOD-FLOW VELOCITIES IN HEALTHY-SUBJECTS [J].
DEMOLIS, P ;
CHALON, S ;
GIUDICELLI, JF .
CLINICAL SCIENCE, 1993, 84 (06) :599-604
[5]   SYSTEMIC, REGIONAL AND CEREBRAL HEMODYNAMIC-EFFECTS OF A NEW ANGIOTENSIN-CONVERTING ENZYME-INHIBITOR, IMIDAPRIL, IN HEALTHY-VOLUNTEERS [J].
DEMOLIS, P ;
ANNANE, D ;
DUHAZE, P ;
GIUDICELLI, JF .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 1994, 8 (01) :80-89
[6]   A TRANSCRANIAL DOPPLER STUDY OF BLOOD-FLOW VELOCITY IN THE MIDDLE CEREBRAL-ARTERIES PERFORMED AT REST AND DURING MENTAL ACTIVITIES [J].
DROSTE, DW ;
HARDERS, AG ;
RASTOGI, E .
STROKE, 1989, 20 (08) :1005-1011
[7]   TRANSCRANIAL DOPPLER IS VALID FOR DETERMINATION OF THE LOWER LIMIT OF CEREBRAL BLOOD-FLOW AUTOREGULATION [J].
LARSEN, FS ;
OLSEN, KS ;
HANSEN, BA ;
PAULSON, OB ;
KNUDSEN, GM .
STROKE, 1994, 25 (10) :1985-1988
[8]   A VALIDATION-STUDY ON THE REPRODUCIBILITY OF TRANSCRANIAL DOPPLER VELOCIMETRY [J].
MAEDA, H ;
ETANI, H ;
HANDA, N ;
TAGAYA, M ;
OKU, N ;
KIM, BH ;
NAKA, M ;
KINOSHITA, N ;
NUKADA, T ;
FUKUNAGA, R ;
ISAKA, Y ;
MATSUMOTO, M ;
KIMURA, K ;
KAMADA, T .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (01) :9-14
[9]   DIFFERENTIAL EFFECT OF 3 CYCLOOXYGENASE INHIBITORS ON HUMAN CEREBRAL BLOOD-FLOW VELOCITY AND CARBON-DIOXIDE REACTIVITY [J].
MARKUS, HS ;
VALLANCE, P ;
BROWN, MM .
STROKE, 1994, 25 (09) :1760-1764
[10]   DEPENDENCY OF BLOOD-FLOW VELOCITY IN THE MIDDLE CEREBRAL-ARTERY ON END-TIDAL CARBON-DIOXIDE PARTIAL-PRESSURE - A TRANSCRANIAL ULTRASOUND DOPPLER STUDY [J].
MARKWALDER, TM ;
GROLIMUND, P ;
SEILER, RW ;
ROTH, F ;
AASLID, R .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1984, 4 (03) :368-372