Meta-regression analysis of high-frequency ventilation vs conventional ventilation in infant respiratory distress syndrome

被引:33
作者
Bollen, Casper W. [1 ]
Uiterwaal, Cuno S. P. M.
van Vught, Adrianus J.
机构
[1] Univ Med Ctr Utrecht, Pediat Intens Care Unit, NL-3508 AB Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3508 AB Utrecht, Netherlands
关键词
conventional mechanical ventilation; high-frequency ventilation; meta-regression analysis; respiratory distress syndrome; infant;
D O I
10.1007/s00134-007-0545-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: There is considerable heterogeneity among randomized trials comparing high-frequency ventilation (HFV) with conventional mechanical ventilation (CMV) in premature neonates with respiratory distress syndrome. We investigated what factors explained differences in outcome among these trials.Design: Meta-regression analysis of 15 randomized trials.Measurements and results: Variables were extracted to explain heterogeneity: year of publication; use of Sensormedics 3100A ventilator for HFV; time on CMV prior to start of study; gestational age; use of surfactant; high lung volume strategy in HFV; and lung protective ventilation strategy in CMV and baseline risk. Chronic lung disease (CLD) and death or CLD were outcome measures. Relative risk ratios were calculated to estimate effect sizes of explanatory variables on reported relative risks. Adjusted estimates of relative risk ratios of high lung volume strategy and lung protective ventilation strategy were 0.42 (95% CI 0.06-2.48) and 2.02 (95% CI 0.18-23.12) for CLD, respectively. The effect of gestational age was less pronounced (RRR = 1.17 (95% CI 0.16-8.32) for CLD, respectively). Use of Sensormedics and prior time on CMV had the smallest effects [RRR = 0.96 (95% CI 0.47-1.94) and RRR = 0.85 (95% CI 0.58-1.24) for CLD, respectively)]. The same results applied to CLD or death as outcome.Conclusions: Variation in ventilation strategies that were used in trials comparing HFV with CMV in premature neonates offered the most likely explanation for the observed differences in the outcome of these trials compared with other explanatory factors.
引用
收藏
页码:680 / 688
页数:9
相关论文
共 26 条
[1]   Cumulative metaanalysis of high-frequency versus conventional ventilation in premature neonates [J].
Bollen, CW ;
Uiterwaal, CSPM ;
van Vught, AJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 168 (10) :1150-1155
[2]  
CLARK RH, 1992, PEDIATRICS, V89, P5
[3]  
Clark RH, 1996, PEDIATRICS, V98, P1058
[4]   High-frequency oscillatory ventilation versus conventional mechanical ventilation for very-low-birth-weight infants [J].
Courtney, SE ;
Durand, DJ ;
Asselin, JM ;
Hudak, ML ;
Aschner, JL ;
Shoemaker, CT .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (09) :643-652
[5]  
Craft Alissa P, 2003, J Perinatol, V23, P14
[6]   Early high-frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation in very low birth weight infants: A pilot study of two ventilation protocols [J].
Durand D.J. ;
Asselin J.M. ;
Hudak M.L. ;
Aschner J.L. ;
Mcartor R.D. ;
Cleary J.P. ;
Vanmeurs K.P. ;
Stewart D.L. ;
Shoemaker C.T. ;
Wiswell T.E. ;
Courtney S.E. .
Journal of Perinatology, 2001, 21 (4) :221-229
[7]  
Froese Alison B, 2005, Crit Care Med, V33, pS115, DOI 10.1097/01.CCM.0000155923.97849.6D
[8]  
Gerstmann DR, 1996, PEDIATRICS, V98, P1044
[9]  
HENDERSONSMART DJ, 2003, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD000104
[10]   Assessing the quality of reports of randomized clinical trials: Is blinding necessary? [J].
Jadad, AR ;
Moore, RA ;
Carroll, D ;
Jenkinson, C ;
Reynolds, DJM ;
Gavaghan, DJ ;
McQuay, HJ .
CONTROLLED CLINICAL TRIALS, 1996, 17 (01) :1-12