Diagnostic performance of a flat-panel detector at low tube voltage in chest radiography -: A phantom study

被引:12
作者
Bernhardt, TM
Rapp-Bernhardt, U
Lenzen, H
Röhl, FW
Diederich, S
Papke, K
Ludwig, K
Heindel, W
机构
[1] Univ Munster, Dept Clin Radiol, D-48129 Munster, Germany
[2] Otto Von Guericke Univ, Dept Biomed & Med Informat, Magdeburg, Germany
[3] Klinikum Duisburg, Dept Radiol & Neuroradiol, Duisburg, Germany
关键词
flat-panel detector; digital radiography; image quality; experimental investigations;
D O I
10.1097/01.rli.0000110566.23154.81
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To evaluate a large area, cesium iodide amorphous silicon flat-panel detector (CsI/a-Si) at 3 tube voltages to detect simulated interstitial lung disease, nodules, and catheters. Methods: Simulated interstitial lung disease, nodules, and catheters were superimposed over a chest phantom. Images were generated at 125 kVp, 90 kVp, and 70 kVp at the same surface dose and reduced effective dose equivalent for 90 kVp and 70 kVp and printed on hard copies. Fifty-four thousand observations were analyzed by receiver operating characteristic (ROC). Results: Detectability of linear, miliary, reticular pattern, and nodules over lucent lung as well as of catheters and nodules over obscured chest areas increased at 90 and/or 70 kVp with higher Az values; however, only it was statistically significant for reticular pattern at 70 kVp and nodules at 90 kVp compared with 125 kVp (P <0.05). The detection of ground-glass pattern was worse at lower kVp (P >0.05). Conclusion: For most simulated patterns, differences in diagnostic performance at 70 kVp/90 kVp and 125 kVp were not significant, except for reticular pattern and nodules over lucent lung.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 12 条
[1]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[2]   Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography [J].
Bernhardt, TM ;
Otto, D ;
Reichel, G ;
Ludwig, K ;
Seifert, S ;
Kropf, S ;
Rapp-Bernhardt, U .
RADIOLOGY, 1999, 213 (02) :445-454
[3]   Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study [J].
Bernhardt, TM ;
Rapp-Bernhardt, U ;
Hausmann, T ;
Reichel, G ;
Krause, UW ;
Doehring, W .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873) :963-968
[4]   Principles of digital radiography with large-area, electronically readable detectors: A review of the basics [J].
Chotas, HG ;
Dobbins, JT ;
Ravin, CE .
RADIOLOGY, 1999, 210 (03) :595-599
[5]   Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector [J].
Dobbins, JT ;
Samei, E ;
Chotas, HG ;
Warp, RJ ;
Baydush, AH ;
Floyd, CE ;
Ravin, CE .
RADIOLOGY, 2003, 226 (01) :221-230
[6]  
DRESSLER G, 1993, ORGAN DOSES XRAY DIA
[7]   Amorphous silicon, flat-panel, X-ray detector versus storage phosphor-based computed radiography:: Contrast-detail phantom study at different tube voltages and detector entrance doses [J].
Hamer, OW ;
Völk, M ;
Zorger, N ;
Feuerbach, S ;
Strotzer, M .
INVESTIGATIVE RADIOLOGY, 2003, 38 (04) :212-220
[8]   EFFECTIVE DOSE EQUIVALENTS, HE, IN DIAGNOSTIC-RADIOLOGY [J].
HUDA, W ;
BISSESSUR, K .
MEDICAL PHYSICS, 1990, 17 (06) :998-1003
[9]   A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography [J].
Launders, JH ;
Kengyelics, SM ;
Cowen, AR .
MEDICAL PHYSICS, 1998, 25 (06) :986-997
[10]   Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography [J].
Launders, JH ;
Cowen, AR ;
Bury, RF ;
Hawkridge, P .
EUROPEAN RADIOLOGY, 2001, 11 (05) :870-875