Advantages of PARAFAC calibration in the determination of malachite green and its metabolite in fish by liquid chromatography-tandem mass spectrometry

被引:45
作者
Arroyo, David [1 ]
Ortiz, M. Cruz [1 ]
Arabia, Luis A. S. [2 ]
Palacios, Francisco [3 ]
机构
[1] Univ Burgos, Fac Sci, Dept Chem, Burgos 09001, Spain
[2] Univ Burgos, Fac Sci, Dept Math & Computat, Burgos 09001, Spain
[3] Diputac Gen Aragon, Dept Hlth & Consumpt, Zaragoza 50004, Spain
关键词
Malachite green; LC-MS/MS; PARAFAC; fish; decision; 2002/657/EC; capability of detection; CC ss;
D O I
10.1016/j.chroma.2008.02.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the properties and advantages of the three-way calibration models based on parallel factor analysis (PARAFAC) in the simultaneous determination of malachite green (MG) and its metabolite (leucomalachite green, LMG) in trout. A recently method proposed by community reference laboratory AFSSA-LERMVD (Fougeres, France) has been used. The method is based on liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) in multiple reaction monitoring (MRM) mode. The validation of the method has been carried out taking into account the Decision 2002/657/EC. The figures of merit for PARAFAC and univariate calibration models of six non-consecutive days analyzed during a month were evaluated. With the samples of the first 3 days, calibration models were built and the fish fortification samples of the other days were predicted. Decision limits (CC alpha, alpha=0.0 1), detection capabilities (CC ss,ss=0.05) and mean relative errors in absolute value (in calibration and with test samples) obtained with PARAFAC calibrations were more homogeneous than the ones obtained with the univariate calibrations, especially in LMG. These figures of merit were in the range of 0.2-0.83 mu g kg(-1) (CC ss) and 0.2-0.49 mu g kg(-1) (CC alpha), whereas mean relative errors in absolute value were in the range of 1.1-7.4% in calibration and 3-12% in test samples for MG and LMG with PARAFAC calibrations. The PARAFAC calibrations allow detecting the test samples which are not similar to the calibration samples and in this way their wrong quantification is avoided. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 37 条
[1]   Quantitative and confirmatory analyses of malachite green and leucomalachite green residues in fish and shrimp [J].
Andersen, WC ;
Turnipseed, SB ;
Roybal, JE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (13) :4517-4523
[2]   The N-way Toolbox for MATLAB [J].
Andersson, CA ;
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2000, 52 (01) :1-4
[3]  
[Anonymous], 1998, Multi-way Analysis in the Food Industry: Models, Algorithms and Applications
[4]  
[Anonymous], STATGRAPHICS PLUS 5
[5]  
[Anonymous], 1994, ISO 5725-1
[6]  
[Anonymous], 1997, 118431 ISO
[7]  
[Anonymous], 1972, PROBABILITY STAT ENG
[8]  
[Anonymous], 2004, MULTIWAY ANAL APPL C
[9]  
[Anonymous], PLS TOOLBOX 4 1 1
[10]   Determination of residues of malachite green in aquatic animals [J].
Bergwerff, AA ;
Scherpenisse, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02) :351-359