Screening for disulfide bonds in proteins by MALDI in-source decay and LIFT-TOF/TOF-MS

被引:86
作者
Schnaible, V
Wefing, S
Resemann, A
Suckau, D
Bücker, A
Wolf-Kummeth, S
Hoffmann, D
机构
[1] Stiftung Caesar, Ctr Adv European Studies & Res, D-53111 Bonn, Germany
[2] Bruker Daltonics Inc, D-28359 Bremen, Germany
关键词
D O I
10.1021/ac025807j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated screening method is presented that uses MALDI in-source decay (MALDI-ISD) of disulfide bonds for identification of disulfide-linked peptides in MALDI mass spectra. Peptides released by ISD of a disulfide bond can be detected at an m/z ratio that corresponds to the singly protonated peptide with a reduced cysteine residue. Therefore, screening of peak lists for signal patterns that fulfill the equation, m/z (peak A) + m/z (peak B) - m/z (H-2 + H+) = m/z (peak C), facilitated identification of putative ISD fragments of disulfide-linked peptides (peaks A and B) and their precursors (peak Q. Signals (peak Q from putatively disulfide-linked peptides were subjected to LIFT-TOF/TOF-MS to confirm the existence of a disulfide bond. Using this method, we identified all 4 disulfide bonds in RNAseA and 8 two-disulfide clusters comprising 16 out of the 17 disulfide bonds in BSA. The presented screening method accelerated the identification of disulfide bonds in RNAseA and BSA, because the number of MS/MS spectra to be acquired was reduced by 1 order of magnitude. Less than 5% of the signals selected for LFT-TOF/TOF-MS did not correspond to disulfide-linked peptides. Furthermore, the number of possible assignments for disulfide-linked peptides was reduced by 2-3 orders of magnitude, because knowledge of the mechanism of disulfide bond fragmentation by ISD permitted use of stricter rules for the interpretation of mass spectra. Therefore, interpretation of MS/ MS spectra of disulfide-linked peptides was considerably simplified in comparison to conventional approaches.
引用
收藏
页码:4980 / 4988
页数:9
相关论文
共 46 条
[1]  
Badock V, 1998, RAPID COMMUN MASS SP, V12, P1952, DOI 10.1002/(SICI)1097-0231(19981215)12:23<1952::AID-RCM420>3.3.CO
[2]  
2-E
[3]   Determination of disulfide structure in agouti-related protein (AGRP) by stepwise reduction and alkylation [J].
Bures, EJ ;
Hui, JO ;
Young, Y ;
Chow, DT ;
Katta, V ;
Rohde, MF ;
Zeni, L ;
Rosenfeld, RD ;
Stark, KL ;
Haniu, M .
BIOCHEMISTRY, 1998, 37 (35) :12172-12177
[4]   Algorithms for identifying protein cross-links via tandem mass spectrometry [J].
Chen, T ;
Jaffe, JD ;
Church, GM .
JOURNAL OF COMPUTATIONAL BIOLOGY, 2001, 8 (06) :571-583
[5]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[6]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[7]  
FRANKEVICH VE, 2002, P 50 ASMS C MASS SPE
[8]   A programmable fragmentation analysis of proteins by in-source decay in MALDI-TOF mass spectrometry [J].
Gao, JL ;
Tsugita, A ;
Takayama, M ;
Xu, L .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1449-1457
[9]   Automated identification of amino acid sequence variations in proteins by HPLC/microspray tandem mass spectrometry [J].
Gatlin, CL ;
Eng, JK ;
Cross, ST ;
Detter, JC ;
Yates, JR .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :757-763
[10]   Top down characterization of larger proteins (45 kDa) by electron capture dissociation mass spectrometry [J].
Ge, Y ;
Lawhorn, BG ;
ElNaggar, M ;
Strauss, E ;
Park, JH ;
Begley, TP ;
McLafferty, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (04) :672-678