Computational techniques for solving the bidomain equations in three dimensions

被引:169
作者
Vigmond, EJ
Aguel, F
Trayanova, NA
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[3] Tulane Univ, Dept Biomed Engn, New Orleans, LA 70118 USA
关键词
bidomain; computer modeling; finite difference; finite-element method; parallel computing;
D O I
10.1109/TBME.2002.804597
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bidomain equations are the most complete description of cardiac electrical activity. Their numerical solution is, however, computationally demanding, especially in three dimensions, because of the fine temporal and spatial sampling required. This paper methodically examines computational performance when solving the bidomain equations. Several techniques to speed up this computation are examined in this paper. The first step was to recast the equations into a parabolic part and an elliptic part. The parabolic part was solved by either the finite-element method (FEM) or the interconnected cable model model (ICCM). The elliptic equation was solved by FEM on a coarser grid than the parabolic problem and at a reduced frequency. The performance of iterative and direct linear equation system solvers was analyzed as well as the scalability and parallelizability of each method. Results indicate that the ICCM was twice as fast as the FEM for solving the parabolic problem, but when the total problem was considered, this resulted in only a 20% decrease in computation time. The elliptic problem could be solved on a coarser grid at one-quarter of the frequency at which the parabolic problem was solved and still maintain reasonable accuracy. Direct methods were faster than iterative methods by at least 50% when a good estimate of the extracellular potential was required. Parallelization over four processors was efficient only when the model comprised at least 500000 nodes. Thus, it was possible to speed up solution of the bidomain equations by an order of magnitude with a slight decrease in accuracy.
引用
收藏
页码:1260 / 1269
页数:10
相关论文
共 26 条
[1]  
Amdahl G. M., 1967, Proceedings of the April 18-20, 1967, spring joint computer conference, AFIPS'67 (Spring), pag, P483, DOI DOI 10.1145/1465482.1465560
[2]   A space-time adaptive method for simulating complex cardiac dynamics [J].
Cherry, EM ;
Greenside, HS ;
Henriquez, CS .
PHYSICAL REVIEW LETTERS, 2000, 84 (06) :1343-1346
[3]   Ionic mechanisms underlying human atrial action potential properties: insights from a mathematical model [J].
Courtemanche, M ;
Ramirez, RJ ;
Nattel, S .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 275 (01) :H301-H321
[4]  
George A., 1981, Computer solutions of large sparse positive definite systems
[5]  
Golub G.H., 2013, MATRIX COMPUTATIONS
[6]  
Harrild DM, 2000, CIRC RES, V87, pE25
[7]   STRUCTURAL COMPLEXITY EFFECTS ON TRANSVERSE PROPAGATION IN A 2-DIMENSIONAL MODEL OF MYOCARDIUM [J].
LEON, LJ ;
ROBERGE, FA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (10) :997-1009
[8]   A DYNAMIC-MODEL OF THE CARDIAC VENTRICULAR ACTION-POTENTIAL .2. AFTERDEPOLARIZATIONS, TRIGGERED ACTIVITY, AND POTENTIATION [J].
LUO, CH ;
RUDY, Y .
CIRCULATION RESEARCH, 1994, 74 (06) :1097-1113
[9]  
Nygren A, 1998, CIRC RES, V82, P63
[10]  
PESKIN CS, 1992, CRIT REV BIOMED ENG, V20, P451