On-line overpressure thin-layer chromatographic separation and electrospray mass spectrometric detection of glycolipids

被引:29
作者
Chai, WG [1 ]
Leteux, C [1 ]
Lawson, AM [1 ]
Stoll, MS [1 ]
机构
[1] Northwick Pk Hosp & Clin Res Ctr, Imperial Coll Sch Med, MRC Glycosci Lab, Harrow HA1 3UJ, Middx, England
关键词
D O I
10.1021/ac025833h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line thin-layer chromatographic separation and electrospray mass spectrometry (TLC/ESI-MS) has been accomplished by direct linking of a commercial overpressure TLC instrument, OPLC 50, and a Q-TOF mass spectrometer. Mass spectrometric detection sensitivity and chromatographic resolution achieved by this configuration were assessed using acidic glycolipids as examples. Under the optimized conditions, a sensitivity of 5 pmol of glycosphingolipid was readily demonstrated for TLC/EST-MS and 20 pmol for TLC/EST-MS/MS production scanning to derive the saccharide sequence and long chain base/fatty acid composition of the ceramide. Initial preconditioning of TLC plates is necessary to achieve high sensitivity detection by reducing chemical background noise. Plates can be used repeatedly (at least 10 times) for analysis, although this may result in a minor reduction in TLC resolution. Following solvent development, separated components on the TLC plates can be detected in the conventional way by nondestructive staining or UV absorption or fluorescence and can be stored for on-line TLC/ESI-MS analysis at a later stage without reduction in mass spectrometric detection sensitivity and chromatographic resolution. Aspects for further improvement of OPLC instrumentation include use of narrower TLC plate dimensions and refined design of the eluate exit system.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 39 条
[1]  
Anderson RM, 1998, JPC-J PLANAR CHROMAT, V11, P336
[2]   USE OF FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY TO IDENTIFY MATERIALS SEPARATED ON HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY PLATES [J].
BARE, KJ ;
READ, H .
ANALYST, 1987, 112 (04) :433-436
[3]   OPTIMAL PROCEDURE FOR COMBINED HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY HIGH-SENSITIVITY LIQUID SECONDARY ION MASS-SPECTROMETRY [J].
CHAI, W ;
CASHMORE, GC ;
CARRUTHERS, RA ;
STOLL, MS ;
LAWSON, AM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (04) :169-178
[4]   Nonreductive release of O-linked oligosaccharides from mucin glycoproteins for structure/function assignments as neoglycolipids: application in the detection of novel ligands for E-selectin [J].
Chai, WG ;
Feizi, T ;
Yuen, CT ;
Lawson, AM .
GLYCOBIOLOGY, 1997, 7 (06) :861-872
[5]   SPECIFICITY OF MILD PERIODATE-OXIDATION OF OLIGOSACCHARIDE-ALDITOLS - RELEVANCE TO THE ANALYSIS OF THE CORE-BRANCHING PATTERN OF O-LINKED GLYCOPROTEIN OLIGOSACCHARIDES [J].
CHAI, WG ;
STOLL, MS ;
CASHMORE, GC ;
LAWSON, AM .
CARBOHYDRATE RESEARCH, 1993, 239 :107-115
[6]   Core-branching pattern and sequence analysis of mannitol-terminating oligosaccharides by neoglycolipid technology [J].
Chai, WG ;
Yuen, CT ;
Feizi, T ;
Lawson, AM .
ANALYTICAL BIOCHEMISTRY, 1999, 270 (02) :314-322
[7]   IDENTIFICATION OF COMPONENTS IN THE BLEOMYCIN COMPLEX BY DIRECT TLC FABMS [J].
CHANG, TT ;
LEE, TM ;
BORDERS, DB .
JOURNAL OF ANTIBIOTICS, 1984, 37 (09) :1098-1100
[8]  
CHANG TT, 1984, ANAL CHEM, V56, P111
[9]   PHASE-TRANSITION MATRIX FOR CHROMATOGRAPHY SECONDARY ION MASS-SPECTROMETRY [J].
DIDONATO, GC ;
BUSCH, KL .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3231-3232
[10]   A SYSTEMATIC NOMENCLATURE FOR CARBOHYDRATE FRAGMENTATIONS IN FAB-MS MS SPECTRA OF GLYCOCONJUGATES [J].
DOMON, B ;
COSTELLO, CE .
GLYCOCONJUGATE JOURNAL, 1988, 5 (04) :397-409