Continuous scanning of the mobility and size distribution of charged clusters and nanometer particles in atmospheric air and the Balanced Scanning Mobility Analyzer BSMA

被引:69
作者
Tammet, H. [1 ]
机构
[1] Univ Tartu, Inst Environm Phys, EE-50090 Tartu, Estonia
关键词
aerosols; size distribution; measurement; electrical methods;
D O I
10.1016/j.atmosres.2006.02.009
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Measuring of charged nanometer particles in atmospheric air is a routine task in research on atmospheric electricity, where these particles are called the atmospheric ions. An aspiration condenser is the most popular instrument for measuring atmospheric ions. Continuous scanning of a mobility distribution is possible when the aspiration condenser is connected as an arm of a balanced bridge. Transfer function of an aspiration condenser is calculated according to the measurements of geometric dimensions, air flow rate, driving voltage, and electric current. The most complicated phase of the calibration is the estimation of the inlet loss of ions due to the Brownian deposition. The available models of ion deposition on the protective inlet screen and the inlet control electrofilter have the uncertainty of about 20%. To keep the uncertainty of measurements low the adsorption should not exceed a few tens of percent. The online conversion of the mobility distribution to the size distribution and a correct reduction of inlet losses are possible when air temperature and pressure are measured simultaneously with the mobility distribution. Two instruments called the Balanced Scanning Mobility Analyzers (BSMA) were manufactured and tested in routine atmospheric measurements. The concentration of atmospheric ions of the size of about a few nanometers is very low and a high air flow rate is required to collect enough of ion current. The air flow of 52 l/s exceeds the air flow in usual aerosol instruments by 2-3 orders of magnitude. The high flow rate reduces the time of ion passage to 60 ms and the heating of air in an analyzer to 0.2 K, which suppresses a possible transformation of ions inside the instrument. The mobility range of the BSMA of 0.032-3.2 cm(2) V-1 s(-1) is logarithmically uniformly divided into 16 fractions. The size distribution is presented by 12 fractions in the diameter range of 0.4-7.5 nm. The measurement noise of a fraction concentration is typically about 5 cm(-3) and the time resolution is about 10 min when measuring simultaneously both positive and negative ions in atmospheric air. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:523 / 535
页数:13
相关论文
共 30 条
[1]   Penetration of nanometer-sized aerosol particles through wire screen and laminar flow tube [J].
Alonso, M ;
Kousaka, Y ;
Hashimoto, T ;
Hashimoto, N .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 27 (04) :471-480
[2]  
CHENG YS, 2001, AEROSOL MEASUREMENT, P537
[3]  
EICEMAN GA, 1994, ION MOBILITY SPECTRO
[4]   On the nature of the ions in air and in carbon dioxide [J].
Erikson, HA .
PHYSICAL REVIEW, 1924, 24 (05) :502-509
[5]  
ERIKSON HA, 1921, PHYS REV, V18, P100
[6]   Experimental and numerical study of the effect of caul-sheets on corner thinning of composite laminates [J].
Fernlund, G ;
Griffith, J ;
Courdji, R ;
Poursartip, A .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2002, 33 (03) :411-426
[7]   History of electrical aerosol measurements [J].
Flagan, RC .
AEROSOL SCIENCE AND TECHNOLOGY, 1998, 28 (04) :301-380
[8]   A condensation nucleus counter (CNC) sensitive to singly charged sub-nanometer particles [J].
Gamero-Castaño, M ;
de la Mora, JF .
JOURNAL OF AEROSOL SCIENCE, 2000, 31 (07) :757-772
[9]   Diurnal variation in the concentration of air ions of different mobility classes in a rural area [J].
Horrak, U ;
Salm, J ;
Tammet, H .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D20)
[10]   Statistical characterization of air ion mobility spectra at Tahkuse Observatory: Classification of air ions [J].
Horrak, U ;
Salm, J ;
Tammet, H .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2000, 105 (D7) :9291-9302