Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques

被引:148
作者
Dennis, MG [1 ]
Simon, JA [1 ]
Kummer, FJ [1 ]
Koval, KJ [1 ]
DiCesare, PE [1 ]
机构
[1] Hosp Joint Dis, Inst Orthopaed, Musculoskeletal Res Ctr, New York, NY 10003 USA
关键词
periprosthetic; femur fracture; cables; cerclage;
D O I
10.1054/arth.2000.4339
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study evaluated 5 currently used periprosthetic femoral shaft fracture fixation techniques to determine which technique provided the greatest fixation stability. Periprosthetic fractures in 30 synthetic femurs were fixed with a plate with cables, plate with proximal cables and distal bicortical screws (Ogden concept), plate with proximal unicortical screws and distal bicortical screws, plate with proximal unicortical screws and cables and distal bicortical screws, or 2 allograft cortical strut grafts with cables. These specimens were then tested in 3 physiologic loading modes. The plate constructs with proximal unicortical screws and distal bicortical screws or with proximal unicortical screws, proximal cables, and distal bicortical screws were significantly more stable in axial compression, lateral bending, and torsional loading than the other fixation constructs studied.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 25 条
[1]  
Beals RK, 1996, CLIN ORTHOP RELAT R, P238
[2]  
BETHEA JS, 1982, CLIN ORTHOP RELAT R, P95
[3]   The treatment of periprosthetic fractures of the femur using cortical onlay allograft struts [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :249-+
[4]   The role of allografts in the treatment of periprosthetic femoral fractures [J].
Chandler, HP ;
Tigges, RG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1422-1432
[5]   FRACTURES OF THE FEMUR IN RELATION TO CEMENTED HIP PROSTHESES [J].
COOKE, PH ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :386-389
[6]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[7]  
DALL DM, 1991, TECH ORTHOP, V6, P7
[8]  
Jensen T T, 1990, J Arthroplasty, V5, P123, DOI 10.1016/S0883-5403(06)80230-5
[9]   FRACTURE OF THE IPSILATERAL FEMUR IN PATIENTS WITH TOTAL HIP-REPLACEMENT [J].
JOHANSSON, JE ;
MCBROOM, R ;
BARRINGTON, TW ;
HUNTER, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1435-1442
[10]   EFFECT OF CIRCUMFERENTIAL BANDS ON CORTICAL VASCULARITY AND VIABILITY [J].
KIRBY, BM ;
WILSON, JW .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (02) :174-179