How do alternative bearing surfaces influence wear behavior?

被引:23
作者
Clarke, Ian C. [1 ]
Manley, Michael T. [2 ]
机构
[1] Loma Linda Univ, Peterson Res Ctr, Loma Linda, CA 92350 USA
[2] Homer Stryker Ctr, Mahwah, NJ USA
关键词
D O I
10.5435/00124635-200800001-00018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Metal, ceramic, and polyethylene liners represent contemporary bearing choices for total joint replacement. Each has limitations in terms of design, sensitivity to manufacturing, and surgical placement. With polyethylene, larger femoral heads represent a design restriction and a potential wear issue. One side benefit is that polyethylene does not click, squeak, or create stripe wear. The attraction of hard-on-hard bearings (metal-on-metal, ceramic-on-ceramic) is that their typically ultra-low wear alleviates concerns with large femoral head designs. However, hard-on-hard bearings produce stripe wear due to the effects of the rigid liner edge. Slight subluxation (microseparation) during swing phase of gait can result in stripe wear on the ball and liner rim. In addition, high levels of implant wear with vertically placed cups can be anticipated. Currently, only alumina-on-alumina bearings can claim virtually no biologic risk. Thus, the role of laboratory studies is to isolate relevant aspects of performance by cup design and to predict the risk-benefit ratios in patients requiring total hip replacement.
引用
收藏
页码:S86 / S93
页数:8
相关论文
共 48 条
[1]  
[Anonymous], SEMIN ARTHROPLAST
[2]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[3]   A benign psoas mass following metal-on-metal resurfacing of the hip [J].
Boardman, DR ;
Middleton, FR ;
Kavanagh, TG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (03) :402-404
[4]   Friction of total hip replacements with different bearings and loading conditions [J].
Brockett, Claire ;
Williams, Sophie ;
Jin, Zhongmin ;
Isaac, Graham ;
Fisher, John .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 81B (02) :508-515
[5]  
BROWN SS, 2007, J BIOMED MAT RES B
[6]   OPTIMUM SIZE OF PROSTHETIC HEADS IN RELATION TO WEAR OF PLASTIC SOCKETS IN TOTAL REPLACEMENT OF HIP [J].
CHARNLEY, J ;
KAMANGAR, A ;
LONGFIELD, MD .
MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01) :31-+
[7]   Current status of zirconia used in total hip implants [J].
Clarke, IC ;
Manaka, M ;
Green, DD ;
Williams, P ;
Pezzotti, G ;
Kim, YH ;
Ries, M ;
Sugano, N ;
Sedel, L ;
Delauney, C ;
Ben Nissan, B ;
Donaldson, T ;
Gustafson, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :73-84
[8]  
CLARKE IC, 1992, CLIN ORTHOP RELAT R, P19
[9]   Current concepts of metal-on-metal hip resurfacing [J].
Clarke, IC ;
Donaldson, T ;
Bowsher, JG ;
Nasser, S ;
Takahashi, T .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2005, 36 (02) :143-+
[10]  
Clarke IC, 2006, SEMIN ARTHROPLASTY, V17, P165