Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS

被引:205
作者
Heitland, Peter [1 ]
Koester, Helmut D. [1 ]
机构
[1] Med Lab Bremen, D-28357 Bremen, Germany
关键词
ICP-MS; blood; trace elements; biomonitoring;
D O I
10.1016/j.jtemb.2006.08.001
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The trace elements Ag, As, Au, B, Ba, Be, Bi, Cd, Ce, Co, Cs, Cu, Ga, Hf, Hg, In, La, Mn, Mo, Ni, Pb, Pd, Rb, Rh, Ru, Sb, Se, Sri, Sr, Te, Th, TI, U, V, W, Y and Zr were determined in 130 human blood samples from occupationally non-exposed volunteers living in the greater area of Bremen in northern Germany. The blood samples were collected in lithium heparin monovettes developed for trace metal determination and were analysed by inductively coupled plasma mass spectrometry (ICP-MS) with an octopole-based collision/reaction cell. For sample introduction into the ICP, the blood samples were diluted 1/10 (V/V) with a 0.1% Triton-X-100 and 0.5% (V/V) ammonia solution. The method validation of our developed routine method is described for all 37 elements and results about internal and external quality assurance are discussed. Information on exposure conditions of all human subjects were collected by questionnaire-based interviews, including smoking habits, seafood consumption and the type of dental alloys in the teeth. Mean values, geometric mean values, ranges and selected percentiles of all elemental concentrations in human blood are presented, which helps toxicologists and clinical chemists planning research about exposition to metals and health effects caused by exposition to metals. (c) 2006 Elsevier GmbH. All rights reserved.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 43 条
[1]   Assessment of the content of selected trace elements in serum of term and pre-term newborns by inductively coupled plasma mass spectrometry [J].
Alimonti, A ;
Petrucci, F ;
Fioravanti, S ;
Laurenti, F ;
Caroli, S .
ANALYTICA CHIMICA ACTA, 1997, 342 (01) :75-81
[2]   Reference values for selected trace elements in serum of term newborns from the urban area of Rome [J].
Alimonti, A ;
Petrucci, F ;
Laurenti, F ;
Papoff, P ;
Caroli, S .
CLINICA CHIMICA ACTA, 2000, 292 (1-2) :163-173
[3]  
ARBOUINE MW, 1992, J TRACE ELEM ELECT H, V6, P153
[4]   Inductively coupled plasma mass spectrometry for direct multi-element analysis of diluted human blood and serum [J].
Barany, E ;
Bergdahl, IA ;
Schutz, A ;
Skerfving, S ;
Oskarsson, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :1005-1009
[5]   Determination of antimony in human blood with inductively coupled plasma-mass spectrometry [J].
Bazzi, A ;
Nriagu, JO ;
Inhorn, MC ;
Linder, AM .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (12) :1251-1254
[6]   German Environmental Survey 1998 (GerES III): environmental pollutants in the urine of the German population [J].
Becker, K ;
Schulz, C ;
Kaus, S ;
Seiwert, M ;
Seifert, B .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2003, 206 (01) :15-24
[7]  
Becker K., 2002, STOFFGEHALTE BLUT UR
[8]   New horizons in human biomonitoring of environmentally and occupationally relevant metals-sector-field ICP-MS versus electrothermal AAS [J].
Begerow, J ;
Turfeld, M ;
Dunemann, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :347-352
[9]   Long-term urinary platinum, palladium, and gold excretion of patients after insertion of noble-metal dental alloys [J].
Begerow, J ;
Neuendorf, J ;
Turfeld, M ;
Raab, W ;
Dunemann, L .
BIOMARKERS, 1999, 4 (01) :27-36
[10]  
BEGEROW J, 2000, ANAL HAZARDOUS SUBST, V7, P97