The etiology of revision total hip arthroplasty: current trends in a retrospective survey of 3450 cases

被引:23
作者
Jonas, Kummerant [1 ,2 ]
Nils, Wirries [1 ]
Alexander, Derksen [1 ]
Stefan, Budde [1 ]
Henning, Windhagen [1 ]
Thilo, Floerkemeier [1 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, Anna von Borries Str 1-7, D-30625 Hannover, Germany
[2] BG Unfallklin Frankfurt Main gGmbH, D-60389 Frankfurt, Germany
关键词
Total hip arthroplasty; Revision hip arthroplasty; Loosening; Disclocation; Trends in hip arthroplasty; DUAL-MOBILITY CUP; FOLLOW-UP; KNEE ARTHROPLASTY; DISLOCATION; INFECTION; POLYETHYLENE; DIAGNOSIS; SURVIVAL; SURVIVORSHIP; REPLACEMENT;
D O I
10.1007/s00402-020-03514-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Introduction Over the last years, the design of implants, the surgical approaches, and diagnostic tools changed in primary and revision of total hip arthroplasty. A knowledge of the different causes for revision after total hip arthroplasty is essential to avoid complications and failures. The purpose of this study was to determine trends of the etiology of implant failures over the last years by analyzing indications of revision hip arthroplasty. Methods All the patients who performed revision hip arthroplasties in our institution between 2001 and 2015 were reviewed retrospectively. Patient demographics, the indication for revision surgery as well as the procedure were assessed. Descriptive statistical analyses and association analyses were performed. Results Within our collective of 3450 revision hip arthroplasties, a total of 20 different indications were identified and categorized. Overall, 80.8% of the revisions were categorized as aseptic, 19.2% as septic implant failures. Some recently debated diagnoses like low-grade infection showed a high increase in incidence, whereas classic failure mechanisms like polyethylene wear showed a decrease over the time. In addition, the data revealed that cup loosening caused more revision surgeries than stem loosening. Conclusion This study successfully updated the current knowledge of different failure mechanisms in revision hip arthroplasties. The data proved that cup loosening was the most common failure mechanism in older patients, while in young patients, septic complications showed a high incidence. Probably, due to improved diagnostic tools, the percentage of infection in revision hip arthroplasty increased over the years.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 43 条
[1]
Dislocationm after revision total hip arthroplasty - An analysis of risk factors and treatment options [J].
Alberton, GM ;
High, WA ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (10) :1788-1792
[2]
Aldinger PR, 2003, ACTA ORTHOP SCAND, V74, P253, DOI 10.1080/00016470310014157
[3]
Navigated cup implantation in hip arthroplasty A meta-analysis [J].
Beckmann, Johannes ;
Stengel, Dirk ;
Tingart, Markus ;
Goetz, Juergen ;
Grifka, Joachim ;
Luering, Christian .
ACTA ORTHOPAEDICA, 2009, 80 (05) :538-544
[4]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[5]
The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[6]
Factors affecting operative time in primary total hip arthroplasty: A retrospective single hospital cohort study of 7674 cases [J].
Bredow, Jan ;
Boese, Christoph Kolja ;
Floerkemeier, Thilo ;
Hellmich, Martin ;
Eysel, Peer ;
Windhagen, Henning ;
Oppermann, Johannes ;
von Lewinski, Gabriela ;
Budde, Stefan .
TECHNOLOGY AND HEALTH CARE, 2018, 26 (05) :857-866
[7]
Vitamin E-blended highly cross-linked polyethylene liners in total hip arthroplasty: a randomized, multicenter trial using virtual CAD-based wear analysis at 5-year follow-up [J].
Busch, Andre ;
Jaeger, Marcus ;
Klebingat, Stefan ;
Baghdadi, Josef ;
Floerkemeier, Thilo ;
Huetter, Felix ;
Grupp, Thomas M. ;
Haversath, Marcel .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (12) :1859-1866
[8]
Survivorship of a Charnley Total Hip Arthroplasty A concise Follow-up, at a Minimum of Thirty-five Years, of Previous Reports [J].
Callaghan, John J. ;
Bracha, Peter ;
Liu, Steve S. ;
Piyaworakhun, Somyot ;
Goetz, Devon D. ;
Johnston, Richard C. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) :2617-2621
[9]
Diagnosing periprosthetic hip joint low-grade infection via arthroscopic neo synovium biopsies [J].
Claassen, Leif ;
Wirries, Nils ;
Ettinger, Sarah ;
Pastor, Marc-Frederic ;
Windhagen, Henning ;
Floerkemeier, Thilo .
TECHNOLOGY AND HEALTH CARE, 2018, 26 (06) :973-982
[10]
Future projections of total hip and knee arthroplasty in the UK: results from the UK Clinical Practice Research Datalink [J].
Culliford, D. ;
Maskell, J. ;
Judge, A. ;
Cooper, C. ;
Prieto-Alhambra, D. ;
Arden, N. K. .
OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (04) :594-600