Appropriate Time Interval to Repeat Ambulatory Blood Pressure Monitoring in Patients With White-Coat Resistant Hypertension

被引:38
作者
Muxfeldt, Elizabeth S. [1 ]
Fiszman, Roberto [1 ]
de Souza, Fabio [1 ]
Viegas, Bianca [1 ]
Oliveira, Fernanda C. [1 ]
Salles, Gil F. [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Internal Med, Univ Hosp Clementino Fraga Filho, Sch Med, Rio De Janeiro, Brazil
关键词
ambulatory blood pressure monitoring; resistant hypertension; white-coat effect; reproducibility; PROGNOSTIC VALUE; OFFICE; VALIDATION; PATTERN; HOME;
D O I
10.1161/HYPERTENSIONAHA.111.185405
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Resistant hypertension is defined as uncontrolled office blood pressure, despite the use of >= 3 antihypertensive drugs. Ambulatory blood pressure monitoring (ABPM) is mandatory to diagnose 2 different groups, those with true and white-coat resistant hypertension. Patients are found to change categories between controlled/uncontrolled ambulatory pressures without changing their office blood pressures. In this way, ABPM should be periodically repeated. The aim of this study was to evaluate the most appropriate time interval to repeat ABPM to assure sustained blood pressure control in patients with white-coat resistant hypertension. This prospective study enrolled 198 patients (69% women; mean age: 68.9 +/- 9.9 years) diagnosed as white-coat resistant hypertension on ABPM. Patients were submitted to a second confirmatory examination 3 months later and repeated twice at 6-month intervals. Statistical analyses included Bland-Altman repeatability coefficients and multivariate logistic regression. Mean office blood pressure was 163 +/- 20/84 +/- 17 mm Hg, and mean 24-hour blood pressure was 118 +/- 8/66 +/- 7 mm Hg. White-coat resistant hypertension diagnosis presented a moderate reproducibility and was confirmed in 144 patients after 3 months. In the third and fourth ABPMs, 74% and 79% of patients sustained the diagnosis. In multivariate regression, a daytime systolic blood pressure <= 115 mm Hg in the confirmatory ABPM triplicated the chance of white-coat resistant hypertension status persistence after 1 year. In conclusion, a confirmatory ABPM is necessary after 3 months of the first white-coat-resistant hypertension diagnosis, and the procedure should be repeated at 6-month intervals, except in patients with daytime systolic blood pressure <= 115 mm Hg, in whom it may be repeated annually. (Hypertension. 2012; 59[part 2]:384-389.)
引用
收藏
页码:384 / 389
页数:6
相关论文
共 30 条
[1]  
Abir-Khalil S, 2009, E MEDITERR HEALTH J, V15, P397
[2]   Reproducibility of white-coat and masked hypertension in ambulatory BP monitoring [J].
Ben-Dov, Iddo Z. ;
Ben-Arie, Liora ;
Mekler, Judith ;
Bursztyn, Michael .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 117 (03) :355-359
[3]   Isolated office hypertension: A prehypertensive state? [J].
Bidlingmeyer, I ;
Burnier, M ;
Bidlingmeyer, M ;
Waeber, B ;
Brunner, HR .
JOURNAL OF HYPERTENSION, 1996, 14 (03) :327-332
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Prevalence of anti-hypertensive treatment adherence in patients with resistant hypertension and validation of three indirect methods for assessing treatment adherence [J].
Bloch, Katia Vergetti ;
de Melo, Andre Nascimento ;
Nogueira, Armando R. .
CADERNOS DE SAUDE PUBLICA, 2008, 24 (12) :2979-2984
[6]   Resistant hypertension: Diagnosis, evaluation, and treatment - A Scientific Statement from the American Heart Association Professional Education Committee of the Council for High Blood Pressure Research [J].
Calhoun, David A. ;
Jones, Daniel ;
Textor, Stephen ;
Goff, David C. ;
Murphy, Timothy P. ;
Toto, Robert D. ;
White, Anthony ;
Cushman, William C. ;
White, William ;
Sica, Domenic ;
Ferdinand, Keith ;
Giles, Thomas D. ;
Falkner, Bonita ;
Carey, Robert M. .
HYPERTENSION, 2008, 51 (06) :1403-1419
[7]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[8]   Clinical Features of 8295 Patients With Resistant Hypertension Classified on the Basis of Ambulatory Blood Pressure Monitoring [J].
de la Sierra, Alejandro ;
Segura, Julian ;
Banegas, Jose R. ;
Gorostidi, Manuel ;
de la Cruz, Juan J. ;
Armario, Pedro ;
Oliveras, Anna ;
Ruilope, Luis M. .
HYPERTENSION, 2011, 57 (05) :898-U74
[9]   Chronotherapy improves blood pressure control and reverts the nondipper pattern in patients with resistant hypertension [J].
Hermida, Ramon C. ;
Ayala, Diana E. ;
Fernandez, Jose R. ;
Calvo, Carlos .
HYPERTENSION, 2008, 51 (01) :69-76
[10]   A validation of the Mobil O Graph (version 12) ambulatory blood pressure monitor [J].
Jones, CR ;
Taylor, K ;
Chowienczyk, P ;
Poston, L ;
Shennan, AH .
BLOOD PRESSURE MONITORING, 2000, 5 (04) :233-238