Optimized separation and determination of methyl sulfone metabolites of polychlorinated biphenyls (PCBs) and p,p′-DDE in biota samples

被引:13
作者
Chu, SG
Covaci, A
Haraguchi, K
Schepens, P
机构
[1] Univ Instelling Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium
[2] Daiichi Coll Pharmaceut Sci, Minami Ku, Fukuoka 81558511, Japan
关键词
D O I
10.1039/b208701d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optimised method is described for the determination of 27 methyl sulfone polychlorobiphenyls ( PCBs) and DDE in biota samples. Initially, the samples were extracted by hot Soxhlet and the methyl sulfones were separated by liquid/liquid extraction with concentrated sulfuric acid and back-extracted with hexane. The parameters of the back-extraction were studied and it was found that for a quantitative extraction of the methyl sulfones from the concentrated acid layer, a 50% dilution with cold water should be done. The hexane layer containing the methyl sulfones was further cleaned-up on basic silica (33% KOH) and Florisil. After concentration, the extract was analysed by gas chromatography-mass spectrometry (GC-MS) with electron capture negative ionisation (ECNI) in selected ion monitoring mode (SIM). It was shown that, for methyl sulfones, the ion formation was dependent on the chlorine substitution, position of the MeSO2-group and the ion source temperature. If the ion source temperature was higher than 200 degreesC, [M-CH3](-) was the predominant ion for most methyl sulfones. Therefore, for increased sensitivity, quantitation of most congeners was done using [M-CH3](-) ions instead of the molecular ion as used in previously reported methods. The method was validated for the determination of 26 tri- to hepta- 3- and 4-substituted MeSO2-PCBs and 3-MeSO2-DDE in animal and human tissues. Good sensitivity and selectivity of the method were obtained. Limits of detection (LODs) ranged from 0.06 to 0.10 ng g(-1) lipid weight. Average recoveries of individual congeners from vegetable oil spiked with individual standards (3.33 ng g(-1)) ranged from 73 to 112% with a mean value of 89%. The coefficients of variation ranged from 5.2 to 12.2%, which is within the acceptable range for environmental analyses.
引用
收藏
页码:1621 / 1626
页数:6
相关论文
共 22 条
[1]   METABOLISM OF 2,4',5-TRICHLOROBIPHENYL BY THE MERCAPTURIC ACID PATHWAY [J].
BAKKE, JE ;
BERGMAN, AL ;
LARSEN, GL .
SCIENCE, 1982, 217 (4560) :645-647
[2]  
BERGMAN A, 1994, ENVIRON TOXICOL CHEM, V13, P121, DOI [10.1897/1552-8618(1994)13[121:PADMSI]2.0.CO
[3]  
2, 10.1002/etc.5620130117]
[4]   DETERMINATION OF METHYL SULFONE-SUBSTITUTED POLYCHLOROBIPHENYLS BY MASS-SPECTROMETRIC TECHNIQUES WITH APPLICATION TO ENVIRONMENTAL-SAMPLES [J].
BUSER, HR ;
ZOOK, DR ;
RAPPE, C .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1176-1183
[5]   ISOLATION AND DETERMINATION OF METHYLSULFONYL-PCBS IN BIOLOGICAL SAMPLES BY SULFURIC-ACID PARTITIONING, ADSORPTION CHROMATOGRAPHY AND GC-ECD [J].
DEVOOGT, P ;
HAGGBERG, L .
CHEMOSPHERE, 1993, 27 (1-3) :271-278
[6]  
Ellerichmann T, 1998, FRESEN ENVIRON BULL, V7, P244
[7]   SYNTHESIS OF PCB METHYLSULFONE - SOME DIFFERENCES IN MASS AND PROTON MAGNETIC-RESONANCE SPECTROSCOPY [J].
HARAGUCHI, K ;
KUROKI, H ;
MASUDA, Y .
CHEMOSPHERE, 1987, 16 (10-12) :2299-2313
[8]   NEGATIVE-ION CHEMICAL-IONIZATION MASS-SPECTROMETRY IN THE ANALYSIS OF POLYCHLORINATED BIPHENYL METHYL SULFONES [J].
HARAGUCHI, K ;
BERGMAN, A ;
JAKOBSSON, E ;
MASUDA, Y .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 347 (10-11) :441-449
[9]   CAPILLARY GAS-CHROMATOGRAPHIC ANALYSIS OF METHYLSULFONE METABOLITES OF POLYCHLORINATED-BIPHENYLS RETAINED IN HUMAN-TISSUES [J].
HARAGUCHI, K ;
KUROKI, H ;
MASUDA, Y .
JOURNAL OF CHROMATOGRAPHY, 1986, 361 :239-252
[10]   An efficient clean-up method for the GC-MS determination of methylsulfonyl-PCBs/DDEs extracted from various marine mammal tissues [J].
Herman, DP ;
Effler, JI ;
Boyd, DT ;
Krahn, MM .
MARINE ENVIRONMENTAL RESEARCH, 2001, 52 (02) :127-150