Dissolution behavior of lipid monolayer-coated, air-filled microbubbles: Effect of lipid hydrophobic chain length

被引:275
作者
Borden, MA [1 ]
Longo, ML [1 ]
机构
[1] Univ Calif Davis, Dept Chem Engn & Mat Sci, Davis, CA 95616 USA
关键词
D O I
10.1021/la026082h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The gas transport properties and dissolution behavior of the lipid monolayer shell coating a micron-scale bubble (microbubble) are of particular interest for developing stable ultrasound contrast agents, drug delivery vehicles, and efficient oxygen carriers. In the current study, Epstein and Plesset's model for the dissolution of a bubble into a quiescent, degassed medium was modified to include a term for the gas permeation resistance of the lipid shell. The shell resistances for a homologous series of phospholipids were determined by comparing this model to experimental data of lipid-coated, air-filled microbubbles dissolving in a degassed aqueous medium. The gas permeation resistance is a significant factor in controlling the dissolution rate of lipid-coated microbubbles and was found to increase monotonically with lipid hydrophobic chain length. During the dissolution process, lipid was shed from the shell in a continuous manner for short-chain lipids to accommodate the shrinking volume of the gas core. A cyclic process of buckling and lipid shedding was observed for long-chain lipids and a mechanism involving adhesive zippering of apposing monolayers is proposed to describe this phenomenon.
引用
收藏
页码:9225 / 9233
页数:9
相关论文
共 57 条
  • [1] ADSORPTION OF CHAIN MOLECULES WITH A POLAR HEAD A-SCALING DESCRIPTION
    ALEXANDER, S
    [J]. JOURNAL DE PHYSIQUE, 1977, 38 (08): : 983 - 987
  • [2] BARRIER PROPERTIES OF POLYACRYLONITRILE
    ALLEN, SM
    FUJII, M
    STANNETT, V
    HOPFENBERG, HB
    WILLIAMS, JL
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1977, 2 (02) : 153 - 164
  • [3] Permeation through monolayers
    Barnes, GT
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1997, 126 (2-3) : 149 - 158
  • [4] CHARACTERISTICS OF ALBUNEX - AIR-FILLED ALBUMIN MICROSPHERES FOR ECHOCARDIOGRAPHY CONTRAST ENHANCEMENT
    BARNHART, J
    LEVENE, H
    VILLAPANDO, E
    MANIQUIS, J
    FERNANDEZ, J
    RICE, S
    JABLONSKI, E
    GJOEN, T
    TOLLESHAUG, H
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 : S162 - S164
  • [5] Preparation of polymeric microbubbles: formulation studies and product characterisation
    Bjerknes, K
    Sontum, PC
    Smistad, G
    Agerkvist, I
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1997, 158 (02) : 129 - 136
  • [6] BLANK M, 1962, RETARDATION EVAPORAT, P75
  • [7] Blank M, 1962, RETARDATION EVAPORAT, P59
  • [8] Science, medicine, and the future - Microbubble contrast agents: a new era in ultrasound
    Blomley, MJK
    Cooke, JC
    Unger, EC
    Monaghan, MJ
    Cosgrove, DO
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7296): : 1222 - 1225
  • [9] Mass-transfer properties of microbubbles. 1. Experimental studies
    Bredwell, MD
    Worden, RM
    [J]. BIOTECHNOLOGY PROGRESS, 1998, 14 (01) : 31 - 38
  • [10] SIMULATION OF EXCHANGES OF MULTIPLE GASES IN BUBBLES IN THE BODY
    BURKARD, ME
    VANLIEW, HD
    [J]. RESPIRATION PHYSIOLOGY, 1994, 95 (02): : 131 - 145