Protein phosphorylation stoichiometry by simultaneous ICP-QMS determination of phosphorus and sulfur oxide ions: A multivariate optimization of plasma operating conditions

被引:22
作者
Ciavardelli, Domenico [1 ,2 ]
Sacchetta, Paolo [2 ]
Federici, Giorgio [3 ,4 ]
Di Illio, Carmine [1 ,2 ]
Urbani, Andrea [3 ,4 ]
机构
[1] CeSI, Chieti, Italy
[2] Univ G DAnnunzio, Dipartimento Sci Biomed, Chieti, Italy
[3] IRCCS Fdn Santa Lucia, Ctr Ric Cervello, Rome, Italy
[4] Univ Roma Tor Vergata, Dept Internal Med, I-00149 Rome, Italy
关键词
Phosphorylation; Proteomics; ICP-MS; Mass spectrometry; MALDI-TOF-MS; CAPILLARY LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; EXPERIMENTAL-DESIGN; MS; ELEMENT; SAMPLES; METAL; INTERFERENCES; CHEMISTRY; REMOVAL;
D O I
10.1016/j.talanta.2009.06.082
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
Molecular mass spectrometry (MS) analysis of protein phosphorylation is partially limited by the molecular specie specificity of the analytical responses that might impair both qualitative and quantitative performances. Elemental MS. such as inductively coupled plasma mass spectrometry (ICP-MS) can overcome these drawbacks: in fact, analytical performance is theoretically independent of the molecular structure of a target analyte naturally containing the elements of interest. Nevertheless, isobaric interferences derived from sample matrix and laboratory environment can hinder the quantitative determination of both phosphorus (P) and sulfur (S) as P-31(+) and S-32(+) by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) under standard plasma conditions. These interferences may be overcome by quantifying P and S as oxide ions (PO+)-P-31-O-16 and (SO+)-S-32-O-16, respectively. In this study, we present a systematic investigation on the effect of plasma instrumental conditions on the oxide ion responses by a design of experiment approach for the simultaneous ICP-QMS determination of P and S ((PO+)-P-31-O-16 and (SO+)-S-32-O-16, respectively) in protein samples without the use of dynamic reaction, collision reaction cells or pre-addition of oxygen as reactant gas in the torch. The proposed method was evaluated in terms of limit of detection, limit of quantification, linearity, repeatability, and trueness. Moreover, detection and quantification capabilities of the optimized method were compared to the standard plasma mode for determination of P-31(+) and S-34(+). Spectral and non-spectral interferences affecting the quantification of P-31(+), (PO+)-P-31-O-16 and (SO+)-S-32-O-16 were also studied. The suitability of inorganic elemental standards for P and S quantification in proteins was assessed. The method was applied to quantify the phosphorylation stoichiometry of commercially available caseins (bovine beta-casein, native and dephosphorylated alpha-casein) and results were confirmed by Matrix Assisted Laser Desorption Ionization Time of Flight MS analysis. We demonstrate that ICP-QMS, by quantifying P and S as oxide ions, was able to accurately calculate the degree of phosphorylation of beta-casein and alpha-casein and to detect specific partial enzymatic dephosphorylation. The collected results might lead to further development of ICP-QMS interfaces optimized for protein phosphorylation studies and for proteomics investigations. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1513 / 1525
页数:13
相关论文
共 56 条
[1]
A metal-coded affinity tag approach to quantitative proteomics [J].
Ahrends, Robert ;
Pieper, Stefan ;
Kuehn, Andreas ;
Weisshoff, Hardy ;
Hamester, Meike ;
Lindemann, Torsten ;
Scheler, Christian ;
Lehmann, Karola ;
Taubner, Kerstin ;
Linscheid, Michael W. .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (11) :1907-1916
[2]
Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[3]
Axelsson BO, 2001, RAPID COMMUN MASS SP, V15, P375, DOI 10.1002/rcm.238
[4]
Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :454-470
[5]
Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1497-1502
[6]
Oxide ion formation of long-lived radionuclides in double-focusing sector field inductively coupled plasma mass spectrometry and their analytical applications [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 202 (1-3) :69-79
[7]
Determination of phosphorus in small amounts of protein samples by ICP-MS [J].
Becker, JS ;
Boulyga, SF ;
Pickhardt, C ;
Becker, J ;
Buddrus, S ;
Przybylski, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (04) :561-566
[8]
Elemental tagging in inorganic mass spectrometric bioanalysis [J].
Bettmer, J. ;
Jakubowski, N. ;
Prange, A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (01) :7-11
[9]
Use of experimental design for optimisation of the cold plasma ICP-MS determination of lithium, aluminum and iron in soft drinks and alcoholic beverages [J].
Bianchi, F ;
Careri, M ;
Maffini, M ;
Mangia, A ;
Mucchino, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (03) :251-256
[10]
Optimisation of the operating conditions of a MC-ICP-MS for the isotopic analysis of gadolinium in spent nuclear fuel using experimental designs [J].
Brennetot, R ;
Becquet, AL ;
Isnard, H ;
Caussignac, C ;
Vailhen, D ;
Chartier, F .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (06) :500-507