High-throughput peptide mass mapping using a microdevice containing trypsin immobilized on a porous polymer monolith coupled to MALDI TOF and ESI TOF mass spectrometers

被引:132
作者
Peterson, DS
Rohr, T
Svec, F
Fréchet, JMJ
机构
[1] EO Lawrence Berkeley Natl Lab, Div Mat Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Ctr New Direct Organ Synth, Dept Chem, Berkeley, CA 94720 USA
关键词
high-throughput protein identification immobilized enzyme; mass spectrometry; monolith; proteomics;
D O I
10.1021/pr0255452
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An enzymatic microreactor with a volume of 470 nL has been prepared by immobilizing trypsin on a 10 cm long reactive porous polymer monolith located in a 100 mum W. fused silica capillary. This reactor affords suitable degrees of digestion of proteins even after very short residence times of less than 1 min. The performance is demonstrated with the digestion of eight proteins ranging in molecular mass from 2848 to 77 754. The digests were analyzed using mass spectrometry in two modes: off-line MALDI and in-line nanoelectrospray ionization. The large numbers of identified peptides enable a high degree of sequence coverage and positive identification of the proteins. The extent of sequence coverage decreases as the molecular mass of the digested protein increases.
引用
收藏
页码:563 / 568
页数:6
相关论文
共 45 条
[1]   Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix [J].
Bengtsson, M ;
Ekström, S ;
Marko-Varga, G ;
Laurell, T .
TALANTA, 2002, 56 (02) :341-353
[2]  
Blackburn RK, 1997, J AM SOC MASS SPECTR, V8, P483
[3]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[4]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[5]  
Dongre AR, 2001, BIOPOLYMERS, V60, P206, DOI 10.1002/1097-0282(2001)60:3<206::AID-BIP10032>3.0.CO
[6]  
2-5
[7]   Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activities [J].
Drott, J ;
Lindstrom, K ;
Rosengren, L ;
Laurell, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (01) :14-23
[8]   Integrated microanalytical technology enabling rapid and automated protein identification [J].
Ekström, S ;
Önnerfjord, P ;
Nilsson, J ;
Bengtsson, M ;
Laurell, T ;
Marko-Varga, G .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :286-293
[9]   Preparation of continuous beds for electrochromatography and reversed-phase liquid chromatography of low-molecular-mass compounds [J].
Ericson, C ;
Liao, JL ;
Nakazato, K ;
Hjerten, S .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :33-41
[10]  
Figeys D, 2002, PROTEOMICS, V2, P373, DOI 10.1002/1615-9861(200204)2:4<373::AID-PROT373>3.0.CO