The gas electron multiplier (GEM)

被引:53
作者
Bouclier, R [1 ]
Capeans, M [1 ]
Dominik, W [1 ]
Hoch, M [1 ]
Labbe, JC [1 ]
Million, G [1 ]
Ropelewski, L [1 ]
Sauli, F [1 ]
Sharma, A [1 ]
机构
[1] VUB,ULB,BRUSSELS,BELGIUM
关键词
D O I
10.1109/23.603726
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe operating principles and results obtained with a new detector element: the Gas Electrons Multiplier(GEM) [1]. Consisting of a thin composite sheet with two metal layers separated by a thin insulator, and pierced by a regular matrix of open channels, the GEM electrode, inserted on the path of electrons in a gas detector, allows the transfer of charge with an amplification factor approaching ten. Uniform response and high rate capability are demonstrated, Coupled to another device, multiwire or micro-strip chamber, the GEM electrode permits higher gains or less critical operation; separation of the sensitive (conversion) volume and the detection volume has other advantages: a built-in delay (useful for triggering purposes), and the possibility of applying high fields on the photo-cathode of ring imaging detectors to improve efficiency. Multiple GEM grids in the same gas volume allow large amplification factors to be achieved in a succession of steps, leading to the realization of an effective gas-filled photomultiplier.
引用
收藏
页码:646 / 650
页数:5
相关论文
共 12 条
[1]   PI-K-P IDENTIFICATION WITH A LARGE-APERTURE RING-IMAGING CHERENKOV COUNTER [J].
ADAMS, M ;
BASTIN, A ;
COUTRAKON, G ;
GLASS, H ;
JAFFE, D ;
KIRZ, J ;
MCCARTHY, R ;
HUBBARD, JR ;
MANGEOT, P ;
MULLIE, J ;
PEISERT, A ;
TICHIT, J ;
BOUCLIER, R ;
CHARPAK, G ;
SANTIARD, JC ;
SAULI, F ;
CRITTENDEN, J ;
HSIUNG, Y ;
KAPLAN, D ;
BROWN, C ;
CHILDRESS, S ;
FINLEY, D ;
ITO, A ;
JONCKHEERE, A ;
JOSTLEIN, H ;
LEDERMAN, L ;
ORAVA, R ;
SMITH, S ;
SUGANO, K ;
UENO, K ;
MAKI, A ;
HEMMI, Y ;
MIYAKE, K ;
NAKAMURA, T ;
SASAO, N ;
SAKAI, Y ;
GRAY, R ;
PLAAG, R ;
ROTHBERG, J ;
RUTHERFOORD, J ;
YOUNG, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (1-2) :237-243
[2]  
Bartol F, 1996, J PHYS III, V6, P337, DOI 10.1051/jp3:1996127
[3]  
BOIMSKA B, 1996, P 5 INT C ADV TECHN
[4]   High rate operation of micro-strip gas chambers on diamond-coated glass [J].
Bouclier, R ;
Capeans, M ;
Million, G ;
Ropelewski, L ;
Sauli, F ;
Temmel, T ;
Cooke, RA ;
Donnel, S ;
Sastri, SA ;
Sonderer, N .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (01) :328-331
[5]   ON SOME FACTORS AFFECTING DISCHARGE CONDITIONS IN MICRO-STRIP GAS-CHAMBERS [J].
BOUCLIER, R ;
CAPEANS, M ;
GARABATOS, C ;
MANZIN, G ;
MILLION, G ;
ROPELEWSKI, L ;
SAULI, F ;
TEMMEL, T ;
SHEKHTMAN, L ;
NAGASLAEV, V ;
PESTOV, Y ;
KULESHOV, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (01) :65-69
[6]  
BOUCLIER R, TN96018 CERN CMS
[7]   CsI UV photocathodes: History and mystery [J].
Breskin, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (1-2) :116-136
[8]   MULTISTEP AVALANCHE CHAMBER - NEW HIGH-RATE, HIGH-ACCURACY GASEOUS DETECTOR [J].
CHARPAK, G ;
SAULI, F .
PHYSICS LETTERS B, 1978, 78 (04) :523-528
[9]   MICROMEGAS: A high-granularity position-sensitive gaseous detector for high particle-flux environments [J].
Giomataris, Y ;
Rebourgeard, P ;
Robert, JP ;
Charpak, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (01) :29-35
[10]  
PESKOV V, 1996, INT C POS SENS DET M